A visual reference for all configurable items within the ProSimB738 Combined Config menu.
This page is a work in progress.
INSTRUCTIONS: Scroll down to the panel drawings and click on a highlighted button, switch, knob or indicator to activate the information panel on the left side. It will tell you what ProSim Config Items are associated with that particular hardware item. Clicking the More Info button that appears in the left panel will take you to a searchable Lookup Table of config items, filtered by that item. Or, you can click the Switch to Lookup Table button below to go to the lookup table directly and search there.
Sincere appreciation to Cockpit Revolution for generously providing the high quality drawings used on this page.
(Note: Some drawings may be slightly altered from author’s originals to accommodate Pro-Sim’s configuration layout)
Table of contents
- Forward Overhead (FWD-OH)
- Aft Overhead (AFT-OH)
- Main Instrument Panel – Captain (MIP-CAPT)
- Main Instrument Panel – Center (MIP-CENTER)
- Main Instrument Panel – First Officer (MIP-FO)
- Mode Control Panel (MCP)
- Electronic Flight Instrument System (EFIS)
- Glare Wings
- Computer Display Units (CDU), Throttle Quadrant (TQ), and Center Pedestal
Forward Overhead (FWD-OH)
FWD-OH
Click an item in the diagram at right to view its basic ProSim Config properties.
Click the More Info button that appears in this panel to visit the Combined Config reference table where you’ll find more detailed information on the item, if available.

APU GEN 1 SWITCH

ProSim System:
Electric
ProSim Group:
Switch
ProSim Config Names:
APU GEN 1 Center
APU GEN 1 Off
APU GEN 1 On
Hardware:
Honeywell 1TL1-7E
Notes:
3-POS Momentary switch (ON)-OFF-(ON)
This position is locked in the center OFF position. You must pull the switch outward to move it to any other position.
For pricing on this part check Octopart
AFT CAB SELECTOR

ProSim System: Pneumatic
ProSim Group: Analog
ProSim Config Names:
AFT CAB selector
Hardware:
10K Potentiometer
ALPHA VANE HEAT L INDICATOR

ALPHA VANE HEAT R INDICATOR

ProSim System: Heating
ProSim Group: Indicator
ProSim Config Names:
Alpha Vane Heat R*
*The ProSim virtual panel shows the indicator incorrectly as “L ALPHA VANE”. It should be “R ALPHA VANE” as per the real aircraft.
ALT HORN CUTOUT SWITCH

ProSim System: Penumatic
ProSim Group: Switch
ProSim Config Names:
Alt horn cutout Off
Alt horn cutout Pushed
Hardware:
Momentary push button, (ON)-OFF
ALTERNATE FLAPS CTRL SWITCH

ProSim System:
Hydraulic
ProSim Group:
Switch
ProSim Config Names:
Alternate flaps ctrl Off
Alternate flaps ctrl Up
Alternate flaps ctrl Down
Hardware:
Honeywell 1TL1-5
Notes:
3-POS ON-OFF-(ON).
UP position – indexed
OFF position – indexed
DOWN position – Momentary ON
Normal position is OFF.
Make sure you orient the switch accordingly.
ALTERNATE FLAPS SWITCH

ProSim System:
Hydraulic
ProSim Group:
Switch
ProSim Config Names:
Alternate flaps Off
Alternate flaps Arm
Hardware:
Honeywell 1TL1-2
Notes:
2-POS ON-OFF
Switch is in OFF position when guard is closed. You do not need to assign the OFF switch position in ProSim Config.
APU FAULT INDICATOR

APU GEN 2 SWITCH

ProSim System: Electric
ProSim Group: Switch
ProSim Config Names:
APU GEN 2 Off*
APU GEN 2 Center
APU GEN 2 On*
*=Momentary
Hardware:
Honeywell 1TL1-7E
3-POS (ON) OFF (ON)
Center-Locking
Spring-loaded to Center position
APU GEN OFF BUS INDICATOR

APU LOW OIL PRESSURE INDICATOR

APU MAINT INDICATOR

APU OVERSPEED INDICATOR

APU SWITCH

ProSim System: Electric
ProSim Group: Switch
ProSim Config Names:
APU Switch Off
APU Switch On
APU Switch Start*
*=Momentary
Hardware:
Honeywell 1TL1-5K
3-POS ON-OFF-(ON)
Spring-loaded from Start to On
ATTEND SWITCH

ProSim System: Misc
ProSim Group: Switch
ProSim Config Names:
Attend Off
Attend Pushed
Hardware:
Momentary push-button, (ON)-OFF
AUTO SLAT FAIL INDICATOR

ProSim System:
Flight Controls
ProSim Group:
Indicator
ProSim Config Names:
Auto slat Fail
Hardware:
Not Available
Notes:
Not Available
AUX PITOT HEAT INDICATOR

BAT DISCHARGE INDICATOR

BATTERY SWITCH

ProSim System: Electric
ProSim Group: Switch
ProSim Config Names:
Battery switch Off
Battery switch On
Hardware:
Honeywell 1TL1-2
Guarded 2-POS ON-OFF
In On position when guarded
BLEED 1 SWITCH

ProSim System: Pneumatic
ProSim Group: Switch
ProSim Config Names:
Bleed 1 Off
Bleed 1 On
Hardware:
Honeywell 1TL1-2D
2-POS ON-OFF
Locked in both positions
BLEED 2 SWITCH

ProSim System: Pneumatic
ProSim Group: Switch
ProSim Config Names:
Bleed 2 Off
Bleed 2 On
Hardware:
Honeywell 1TL1-2D
2-POS ON-OFF
Locked in both positions
BLEED APU SWITCH

ProSim System: Pneumatic
ProSim Group: Switch
ProSim Config Names:
Bleed APU Off
Bleed APU On
Hardware:
Honeywell 1TL1-2D
2-POS ON-OFF
Locked in both positions
BLEED TRIP OFF 1 INDICATOR

BLEED TRIP OFF 2 INDICATOR

BUS TRANSFER SWITCH

ProSim System: Electric
ProSim Group: Switch
ProSim Config Names:
Bus transfer switch Off
Bus transfer switch Auto
Hardware:
Honeywell 1TL1-1
Guarded 2-POS ON-OFF
In Auto position when guarded
CABIN TEMP SELECTOR SWITCH

ProSim System: Misc
ProSim Group: Indicator
ProSim Config Names:
Air Temp Selector CONT CAB
Air Temp Selector DUCT FWD
Air Temp Selector DUCT AFT
Air Temp Selector CAB FWD
Air Temp Selector CAB AFT
Air Temp Selector R
Air Temp Selector L
Hardware:
8-Position Rotary Switch
CABIN TEMPERATURE GAUGE

CABIN VSI GAUGE

CALL INDICATOR

CAPT PITOT HEAT INDICATOR

CONT CAB SELECTOR

ProSim System: Pneumatic
ProSim Group: Analog
ProSim Config Names:
CONT CAB selector
Hardware:
10K Potentiometer
COPILOT PITOT HEAT INDICATOR

ProSim System: Heating
ProSim Group: Indicator
ProSim Config Names:
Copilot Pitot Heat*
*NOTE: This is the correct item name for the “F/O PITOT” indicator
COWL ANTI-ICE L INDICATOR

COWL ANTI-ICE R INDICATOR

COWL VALVE OPEN L INDICATOR

ProSim System: Heating
ProSim Group: Indicator
ProSim Config Names:
Cowl valve open L
Cowl valve open L bright (GATE)*
*This is a dual-brightness indicator. The bright state is activated by a gate. Bright indicates the valve is in transit and dim indicates a full open state.
COWL VALVE OPEN R INDICATOR

ProSim System: Heating
ProSim Group: Indicator
ProSim Config Names:
Cowl valve open R
Cowl valve open R bright (GATE)*
*This is a dual-brightness indicator. The bright state is activated by a gate. Bright indicates the valve is in transit and dim indicates a full open state.
CROSSFEED INDICATOR

ProSim System: Fuel
ProSim Group: Indicator
ProSim Config Names:
Crossfeed indicator
Crossfeed indicator bright
This is a dual-brightness indicator
CROSSFEED SWITCH

ProSim System: Fuel
ProSim Group: Switch
ProSim Config Names:
Crossfeed Off
Crossfeed On
Hardware:
Honeywell 7AS12
90 Degree 2-POS Rotary
Knob P/N BP073-109
DISCONNECT 1 SWITCH

ProSim System: Electric
ProSim Group: Switch
ProSim Config Names:
Disconnect 1 Normal
Disconnect 1 Off
Hardware:
Honeywell 1TL1-2
Guarded 2-POS ON-OFF
In Normal position when guarded
DISCONNECT 2 SWITCH

ProSim System: Electric
ProSim Group: Switch
ProSim Config Names:
Disconnect 2 Normal
Disconnect 2 Off
Hardware:
Honeywell 1TL1-2
Guarded 2-POS ON-OFF
In Normal position when guarded
DISPLAY CONTROL PANEL SWITCH

ProSim System:
Misc
ProSim Group:
Switch
ProSim Config Names:
Display Control Panel Normal
Display Control Panel Both on 1
Display Control Panel Both on 2
Hardware:
Not Available
Notes:
Not Available
DISPLAY SOURCE SWITCH

ProSim System:
Misc
ProSim Group:
Switch
ProSim Config Names:
Display source Auto
Display source All on 1
Display source All on 2
Hardware:
Not Available
Notes:
Not Available
DOOR AFT CARGO INDICATOR

DOOR AFT ENTRY INDICATOR

DOOR AFT SERVICE INDICATOR

DOOR AIR STAIRS INDICATOR

DOOR EQUIP INDICATOR

DOOR FWD CARGO INDICATOR

DOOR FWD ENTRY INDICATOR

DOOR FWD SERVICE INDICATOR

DOOR LEFT AFT OVERWING INDICATOR

DOOR LEFT FWD OVERWING INDICATOR

DOOR RIGHT AFT OVERWING INDICATOR

DOOR RIGHT FWD OVERWING INDICATOR

DRIVE 1 INDICATOR

DRIVE 2 INDICATOR

DUAL BLEED INDICATOR

ELEC MAINT SWITCH

ProSim System: Electric
ProSim Group: Switch
ProSim Config Names:
Elec maint Off
Elec maint Pushed
Hardware:
Momentary push button, (ON)-OFF
ELEC PNL AC SWITCH

ProSim System: Electric
ProSim Group: Switch
ProSim Config Names:
Elec Pnl AC STBY PWR
Elec Pnl AC GRD PWR
Elec Pnl AC GEN1
Elec Pnl AC APU GEN
Elec Pnl AC GEN2
Elec Pnl AC INV
Elec Pnl AC TEST
Hardware:
8 Position Rotary Switch
(restricted to 7 positions)
ELEC PNL DC SWITCH

ProSim System: Electric
ProSim System: Switch
ProSim Config Names:
Elec Pnl DC STBY PWR
Elec Pnl DC BAT BUS
Elec Pnl DC BAT
Elec Pnl DC AUX BAT
Elec Pnl DC TR1
Elec Pnl DC TR2
Elec Pnl DC TR3
Elec Pnl DC TEST
Hardware:
8 Position Rotary Switch
ELECTRIC PANEL LCD

ELEV PITOT HEAT L INDICATOR

ELEV PITOT HEAT R INDICATOR

EMER EXIT LIGHTS SWITCH

ProSim System: Lighting
ProSim Group: Switch
ProSim Config Names:
Emer Exit Light Off
Emer Exit Lights Armed
Emer Exit Lights On
ON position is the active state when guard is closed.
Hardware:
Honeywell ITL1-1
3-POS ON-OFF-ON
EMERG EXIT LIGHTS NOT ARMED INDICATOR

ProSim System: Lighting
ProSim Group: Indicator
ProSim Config Names:
Emerg Exit Lights not armed
ENG ANTI-ICE 1 SWITCH

ProSim System: Heating
ProSim Group: Switch
ProSim Config Names:
Eng Anti-Ice 1 Off
Eng Anti-Ice 1 On
Hardware:
Honeywell 1TL1-2D
2-POS ON-OFF
Locked in both positions
ENG ANTI-ICE 2 SWITCH

ProSim System: Heating
ProSim Group: Switch
ProSim Config Names:
Eng Anti-Ice 2 Off
Eng Anti-Ice 2 On
Hardware:
Honeywell 1TL1-2D
2-POS ON-OFF
Locked in both positions
ENG VALVE CLOSED L INDICATOR

ProSim System:
Fuel
ProSim Group:
Indicator
Gate
ProSim Config Names:
ENG Valve Closed L
ENG Valve Closed L bright
Hardware:
Not Available
Notes:
Dual brightness indicator. ENG Valve Closed L sets the indicator brightness to normal brightness. The ENG Valve Closed L bright gate sets the indicator brightness to bright.
ENG VALVE CLOSED R INDICATOR

ProSim System:
Fuel
ProSim Group:
Indicator
Gate
ProSim Config Names:
ENG Valve Closed R
ENG Valve Closed R bright
Hardware:
Not Available
Notes:
Dual brightness indicator. ENG Valve Closed R sets the indicator brightness to normal brightness. The ENG Valve Closed R bright gate sets the indicator brightness to bright.
EQUIP COOLING EXAUST OFF INDICATOR

ProSim System: Misc
ProSim Group: Indicator
ProSim Config Names:
Equip cooling exhaust Off
EQUIP COOLING EXAUST SWITCH

ProSim System: Misc
ProSim Group: Switch
ProSim Config Names:
Equip cooling exhaust Normal
Equip cooling exhaust Alternate
Hardware:
Honeywell 1TL1-2
2-POS ON-OFF
EQUIP COOLING SUPPLY OFF INDICATOR

EQUIP COOLING SUPPLY SWITCH

ProSim System: Misc
ProSim Group: Switch
ProSim Config Names:
Equip cooling supply Normal
Equip cooling supply Alternate
Hardware:
Honeywell 1TL1-2
2-POS ON-OFF
FEEL DIFF PRESS INDICATOR

ProSim System:
Hydraulic
ProSim Group:
Indicator
ProSim Config Names:
Feel Diff Press
Hardware:
Not Available
Notes:
Not Available
FILTER BYPASS L INDICATOR

ProSim System:
Fuel
ProSim Group:
Indicator
ProSim Config Names:
Filter Bypass L
Hardware:
Not Available
Notes:
Not Available
FILTER BYPASS R INDICATOR

ProSim System:
Fuel
ProSim Group:
Indicator
ProSim Config Names:
Filter Bypass R
Hardware:
Not Available
Notes:
Not Available
FLT ALT DISPLAY

FLT CTRL A SWITCH

ProSim System:
Hydraulic
ProSim Group:
Switch
ProSim Config Names:
Flt Ctrl A Off
Flt Ctrl A Stby Rud
Flt Ctrl A A On
Hardware:
Honeywell 1TL1-1
Notes:
3-POS ON-OFF-ON
You do not need to assign the OFF position to ProSim.
Associate one ON switch position to the STBY RUD and then assign to ProSim Config item “Flt Ctrl A Stby Rud”.
Associate the other ON switch position to the A ON and then assign to ProSim Config item “Flt Ctrl A A On”.
FLT CTRL B SWITCH

ProSim System:
Hydraulic
ProSim Group:
Switch
ProSim Config Names:
Flt Ctrl B Off
Flt Ctrl B Stby Rud
Flt Ctrl B B On
Hardware:
Honeywell 1TL1-1
Notes:
3-POS ON-OFF-ON
You do not need to assign the OFF position to ProSim.
Associate one ON switch position to the STBY RUD and then assign to ProSim Config item “Flt Ctrl B Stby Rud”.
Associate the other ON switch position to the A ON and then assign to ProSim Config item “Flt Ctrl B B On”.
FLT CONTROL LOW PRESSURE A INDICATOR

ProSim System:
Hydraulic
ProSim Group:
Indicator
ProSim Config Names:
FLT Control low pressure A
Hardware:
Not Available
Notes:
None
FLT CONTROL LOW PRESSURE B INDICATOR

ProSim System:
Hydraulic
ProSim Group:
Indicator
ProSim Config Names:
FLT Control low pressure B
Hardware:
Not Available
Notes:
None
FLIGHT ALT ENCODER

ProSim System: Pneumatic
ProSim Group: Encoder
ProSim Config Names:
Flight alt in encoder
NOTE: other related inputs include:
Flight alt in encoder pulse down Off (SWITCH)
Flight alt in encoder pulse down On (SWITCH)
Flight alt in encoder pulse up Off (SWITCH)
Flight alt in encoder pulse up On (SWITCH)
Flight alt in (ANALOG)
Hardware:
Continuous rotary encoder switch
FMC NAV SWITCH

ProSim System:
Navigation
ProSim Group:
Switch
ProSim Config Names:
FMC Normal
FMC Both on L
FMC Both on R
Hardware:
Not Available
Notes:
Not Available
FUEL CENTER LEFT LP INDICATOR

FUEL CENTER LEFT SWITCH

ProSim System: Fuel
ProSim Group: Switch
ProSim Config Names:
Fuel Center Left Off
Fuel Center Left On
Hardware:
Honeywell 1TL1-2D
2-POS ON-OFF
Locked in both positions
FUEL CENTER RIGHT LP INDICATOR

FUEL CENTER RIGHT SWITCH

ProSim System: Fuel
ProSim Group: Switch
ProSim Config Names:
Fuel Center Right Off
Fuel Center Right On
Hardware:
Honeywell 1TL1-2D
2-POS ON-OFF
Locked in both positions
FUEL LEFT AFT LP INDICATOR

FUEL LEFT AFT SWITCH

ProSim System: Fuel
ProSim Group: Switch
ProSim Config Names:
Fuel Left Aft Off
Fuel Left Aft On
Hardware:
Honeywell 1TL1-2D
2-POS ON-OFF
Locked in both positions
FUEL LEFT FWD LP INDICATOR

FUEL LEFT FWD SWITCH

ProSim System: Fuel
ProSim Group: Switch
ProSim Config Names:
Fuel Left Fwd Off
Fuel Left Fwd On
Hardware:
Honeywell 1TL1-2D
2-POS ON-OFF
Locked in both positions
FUEL RIGHT FWD SWITCH

ProSim System: Fuel
ProSim Group: Switch
ProSim Config Names:
Fuel Right Fwd Off
Fuel Right Fwd On
Hardware:
Honeywell 1TL1-2D
2-POS ON-OFF
Locked in both positions
FUEL RIGHT AFT LP INDICATOR

FUEL RIGHT AFT SWITCH

ProSim System: Fuel
ProSim Group: Switch
ProSim Config Names:
Fuel Right Aft Off
Fuel Right Aft On
Hardware:
Honeywell 1TL1-2D
2-POS ON-OFF
Locked in both positions
FUEL RIGHT FWD LP INDICATOR

FUEL TEMPERATURE GAUGE

ProSim System:
Fuel
ProSim Group:
Gauge
ProSim Config Names:
Fuel Temperature
Hardware:
Not Available
Notes:
Not Available
FWD CAB SELECTOR

ProSim System: Pneumatic
ProSim Group: Analog
ProSim Config Names:
FWD CAB selector
Hardware:
10K Potentiometer
GALLEY SWITCH

ProSim System: Electric
ProSim Group: Switch
ProSim Config Names:
Galley Off
Galley On
Hardware:
Honeywell 1TL12
2-POS ON-OFF
GEN OFF BUS 1 INDICATOR

GEN OFF BUS 2 INDICATOR

GEN 1 SWITCH

ProSim System: Electric
ProSim Group: Switch
ProSim Config Names:
GEN 1 Off*
GEN 1 Center
GEN 1 On*
*=Momentary
Hardware:Honeywell 1TL1-7E
3-POS (ON)-OFF-(ON)
Center-Locking
Spring-loaded to Center position
GEN 2 SWITCH

ProSim System: Electric
ProSim Group: Switch
ProSim Config Names:
GEN 2 Off*
GEN 2 Center
GEN 2 On*
*=Momentary
Hardware:
Honeywell 1TL1-7E
3-POS (ON)-OFF-(ON)
Center-Locking
Spring-loaded to Center position
GROUND CALL SWITCH

ProSim System: Misc
ProSim Group: Switch
ProSim Config Names:
Ground call Off
Ground call Pushed
Hardware:
Momentary push-button, (ON)-OFF
GROUND POWER AVAILABLE INDICATOR

GROUND POWER SWITCH

ProSim System: Electric
ProSim Group: Switch
ProSim Config Names:
Ground Power Off*
Ground Power Center
Ground Power On*
*=Momentary
Hardware:
Honeywell 1TL1-7E
3-POS (ON)-OFF-(ON)
Center-Locking
Spring-loaded to Center
HYD ELEC1 LP INDICATOR

HYD ELEC2 LP INDICATOR

HYD ELEC1 OVHT INDICATOR

HYD ELEC2 OVHT INDICATOR

HYD ELEC1 SWITCH

ProSim System: Hydraulic
ProSim Group: Switch
ProSim Config Names:
Hyd ELEC1 Off
Hyd ELEC1 On
Hardware:
Honeywell 1TL1-2D
2-POS ON-OFF
Locked in both positions
HYD ELEC2 SWITCH

ProSim System: Hydraulic
ProSim Group: Switch
ProSim Config Names:
Hyd ELEC2 Off
Hyd ELEC2 On
Hardware:
Honeywell 1TL1-2D
2-POS ON-OFF
Locked in both positions
HYD ENG1 LP INDICATOR

HYD ENG2 LP INDICATOR

HYD ENG1 SWITCH

ProSim System: Hydraulic
ProSim Group: Switch
ProSim Config Names:
Hyd ENG1 Off
Hyd ENG1 On
Hardware:
Honeywell 1TL1-2D
2-POS ON-OFF
Locked in both positions
HYD ENG2 SWITCH

ProSim System: Hydraulic
ProSim Group: Switch
ProSim Config Names:
Hyd ENG2 Off
Hyd ENG2 On
Hardware:
Honeywell 1TL1-2D
2-POS ON-OFF
Locked in both positions
HYD STANDBY LOW PRESSURE INDICATOR

ProSim System:
Hydraulic
ProSim Group:
Indicator
ProSim Config Names:
Hyd standby low pressure
Hardware:
Not Available
Notes:
None
HYD STANDBY LOW QUANTITY INDICATOR

ProSim System:
Hydraulic
ProSim Group:
Indicator
ProSim Config Names:
Hyd standby low quantity
Hardware:
Not Available
Notes:
None
IGNITION SELECT SWITCH

ProSim System: Electric
ProSim Group: Switch
ProSim Config Names:
Ignition select Both
Ignition select Left
Ignition select Right
Hardware:
Honeywell 1TL1-1
3-POS ON-OFF-ON
IRS NAV SWITCH

ProSim System:
Navigation
ProSim Group:
Switch
ProSim Config Names:
IRS Normal
IRS Both on L
IRS Both on R
Hardware:
Not Available
Notes:
Not Available
LAND ALT ENCODER

ProSim System: Pneumatic
ProSim Group: Encoder
ProSim Config Names:
Land alt in encoder
NOTE: other related inputs include:
Land alt in encoder pulse down Off (SWITCH)
Land alt in encoder pulse down On (SWITCH)
Land alt (NUMERICAL)
Land alt in (ANALOG)
Hardware:
Continuous rotary encoder switch
LAVATORY SMOKE INDICATOR

LIGHT MAIN RETRACT SWITCHES

ProSim System: Lighting
ProSim Group: Switch
ProSim Config Names:
For 2-Position Variation:
Light Main Retract L On
Light Main Retract L Off
Light Main Retract R On
Light Main Retract R Off
For 3-Position Variation:
Light Main Retract L 3 POS Retracted
Light Main Retract L 3 POS Extended
Light Main Retract L 3 POS On
Light Main Retract R 3 POS Retracted
Light Main Retract R 3 POS Extended
Light Main Retract R 3 POS On
Hardware:
2-POS ON-OFF, Honeywell 1TL133-2
3-POS ON-OFF-ON, Honeywell 1TL133-1
LIGHT MAIN FIXED SWITCHES

ProSim System: Lighting
ProSim Group: Switch
ProSim Config Names:
Light Main Fixed L On
Light Main Fixed L Off
Light Main Fixed R On
Light Main Fixed R Off
Hardware:
Honeywell 1TL133-2
2-POS ON-OFF
LIGHTS ANTI COLLISION SWITCH

ProSim System: Lighting
ProSim Group: Switch
ProSim Config Names:
Lights Anti collision Off
Lights Anti collision On
Hardware:
Honeywell 1TL1-2
2-POS ON-OFF
LIGHTS LOGO SWITCH

ProSim System: Lighting
ProSim Group: Switch
ProSim Config Names:
Lights Logo Off
Lights Logo On
Hardware:
Honeywell 1TL1-2
2-POS ON-OFF
LIGHTS POSITION SWITCH

ProSim System: Lighting
ProSim Group: Switch
ProSim Config Names:
Lights Position Off
Lights Position On
Hardware:
Honeywell 1TL1-2
2-POS ON-OFF
NOTE: This is designed for the separate Strobe and Position switches. If your strobe light switch is a combined 3-position “Position Strobe & Steady”switch, use the Strobe switch config item instead and assign the 3 positions to it.
LIGHTS RUNWAY TURNOFF SWITCHES

ProSim System: Lighting
ProSim Group: Switch
ProSim Config Names:
Lights Runway turnoff L On
Lights Runway turnoff L Off
Lights Runway turnoff R On
Lights Runway turnoff R Off
Hardware:
Honeywell 1TL1-2
2-POS ON-OFF
LIGHTS STROBE SWITCH

ProSim System: Lighting
ProSim Group: Switch
ProSim Config Names:
2-POS:
Lights Strobe Off
Lights Strobe On
OR
3-POS:
Lights Strobe & Steady Strobe & Steady
Lights Strobe & Steady Off
Lights Strobe & Steady Steady
Hardware:
For 2-POS: Honeywell 1TL1-2 ON-OFF
For 3-POS: Honeywell 1TL1-1 ON-OFF-ON
LIGHTS TAXI SWITCH

ProSim System: Lighting
ProSim Group: Switch
ProSim Config Names:
Lights Taxi On
Lights Taxi Off
Hardware:
Honeywell 1TL1-2
2-POS ON-OFF
LIGHTS WHEEL WELL SWITCH

ProSim System: Lighting
ProSim Group: Switch
ProSim Config Names:
Lights Wheel well Off
Lights Wheel well On
Hardware:
Honeywell 1TL1-2
2-POS ON-OFF
LIGHTS WING SWITCH

ProSim System: Lighting
ProSim Group: Switch
ProSim Config Names:
Lights Wing Off
Lights Wing On
Hardware:
Honeywell 1TL1-2
2-POS ON-OFF
MACH TRIM FAIL INDICATOR

ProSim System:
Misc
ProSim Group:
Indicator
ProSim Config Names:
Mach Trim Fail
Hardware:
Not Available
Notes:
Not Available
NO SMOKING SWITCH

ProSim System: Misc
ProSim Group: Switch
ProSim Config Names:
No Smoking Off
No Smoking Auto
No Smoking On
Hardware:
Honeywell 1TL1-1
3-POS ON-OFF-ON
OFF SCHED DESCENT INDICATOR

OUTFLOW VALVE POSITION GAUGE

OUTFLOW VALVE SWITCH

ProSim System: Pneumatic
ProSim Group: Switch
ProSim Config Names:
Outflow valve Off
Outflow valve Open
Outflow valve Close
Hardware:
Honeywell 1TL1-7
3-POS (ON)-OFF-(ON)
OVHT TEST

ProSim System: Pneumatic
ProSim Group: Switch
ProSim Config Names:
OVHT test Off
OVHT test On
Hardware:
Momentary push button (ON)-OFF
PACK 1 SWITCH

ProSim System: Pneumatic
ProSim Group: Switch
ProSim Config Names:
Pack 1 Auto
Pack 1 High
Pack 1 Off
Hardware:
Honeywell 1TL1-1A
3-POS ON-OFF-ON
Locked in all 3 positions
PACK 2 SWITCH

ProSim System: Pneumatic
ProSim Group: Switch
ProSim Config Names:
Pack 1 Auto
Pack 1 High
Pack 1 Off
Hardware:
Honeywell 1TL1-1A
3-POS ON-OFF-ON
Locked in all 3 positions
PACK L INDICATOR

PACK R INDICATOR

PNEUMATIC ISOLATION SWITCH

ProSim System: Pneumatic
ProSim Group: Switch
ProSim Config Names:
Pneumatic Isolation switch Open
Pneumatic Isolation switch Auto
Pneumatic Isolation switch Close
Hardware:
Honeywell 1TL1-1A
3-POS ON-OFF-ON
Locked in all 3 positions
PRESSURE DIFFERENTIAL GAUGE

PRESSURE GAUGE

ProSim System: Pneumatic
ProSim Group: Gauge
ProSim Config Names:
Pressure Left
Pressure Right
PRESSURIZATION ALTN INDICATOR

PRESSURIZATION AUTO FAIL INDICATOR

ProSim System: Pneumatic
ProSim Group: Indicator
ProSim Config Names:
Pressurization auto fail
PRESSURIZATION MANUAL INDICATOR

ProSim System: Pneumatic
ProSim Group: Indicator
ProSim Config Names:
Pressurization manual
PRESSURIZATION SWITCH

ProSim System: Pneumatic
ProSim Group: Switch
ProSim Config Names:
Pressurization Auto
Pressurization Altn
Pressurization Man
Hardware:
8-POS rotary switch limited to 3 positions
PROBE HEAT A SWITCH

ProSim System: Heating
ProSim Group: Switch
ProSim Config Names:
Probe heat A OFF
Probe heat A ON
Hardware:
Honeywell 1TL1-w
2-POS ON-OFF
PROBE HEAT B SWITCH

ProSim System: Heating
ProSim Group: Switch
ProSim Config Names:
Probe heat B OFF
Probe heat B ON
Hardware:
Honeywell 1TL1-w
2-POS ON-OFF
RAM DOOR FULL OPEN L INDICATOR

ProSim System: Pneumatic
ProSim Group: Indicator
ProSim Config Names:
Ram door full open L
Ram door full open L bright (GATE)
RAM DOOR FULL OPEN R INDICATOR

ProSim System: Pneumatic
ProSim Group: Indicator
ProSim Config Names:
Ram door full open R
Ram door full open R bright (GATE)
RECIRC FAN L SWITCH

ProSim System: Pneumatic
ProSim Group: Switch
ProSim Config Names:
Recirc Fan L Auto
Recirc Fan L Off
Recirc Fan L running (GATE)
Hardware:
Honeywell 1TL1-2
2-POS ON-OFF
RECIRC FAN R SWITCH

ProSim System: Pneumatic
ProSim Group: Switch
ProSim Config Names:
Recirc Fan R Auto
Recirc Fan R Off
Recirc Fan R running (GATE)
Hardware:
Honeywell 1TL1-2
2-POS ON-OFF
SEATBELT SWITCH

ProSim System: Misc
ProSim Group: Switch
ProSim Config Names:
Seatbelt Off
Seatbelt Auto
Seatbelt On
Hardware:
Honeywell 1TL1-1
3-POS ON-OFF-ON
SOURCE OFF 1 INDICATOR

SOURCE OFF 2 INDICATOR

SPAR VALVE CLOSED L INDICATOR

ProSim System:
Fuel
ProSim Group:
Indicator
Gate
ProSim Config Names:
SPAR Valve Closed L
SPAR Valve Closed L bright
Hardware:
Not Available
Notes:
Dual brightness indicator. SPAR VALVE CLOSED L config item sets the indicator to normal brightness. The SPAR Valve Closed L bright gate sets the indicator to bright.
SPAR VALVE CLOSED R INDICATOR

ProSim System:
Fuel
ProSim Group:
Indicator
Gate
ProSim Config Names:
SPAR Valve Closed R
SPAR Valve Closed R bright
Hardware:
Not Available
Notes:
Dual brightness indicator. SPAR VALVE CLOSED R config item sets the indicator to normal brightness. The SPAR Valve Closed R bright gate sets the indicator to bright.
SPEED TRIM FAIL INDICATOR

ProSim System:
Flight Controls
ProSim Group:
Indicator
ProSim Config Names:
Speed Trim Fail
Hardware:
Not Available
Notes:
Not Available
SPOILER A SWITCH

ProSim System:
Hydraulic
ProSim Group:
Switch
ProSim Config Names:
Spoiler A Off
Spoiler A On
Hardware:
Honeywell 1TL1-2
Notes:
2 Position, ON-OFF
SPOILER B SWITCH

ProSim System:
Hydraulic
ProSim Group:
Switch
ProSim Config Names:
Spoiler B Off
Spoiler B On
Hardware:
Honeywell 1TL1-2
Notes:
2-Position, ON-OFF
STANDBY POWER OFF INDICATOR

STANDBY POWER SWITCH

ProSim System: Electric
ProSim Group: Switch
ProSim Config Names:
Standby power switch Off
Standby power switch Bat
Standby power switch Auto
Hardware:
Honeywell 1TL1-1
3-POS ON-OFF-ON
Defaults to Auto position when Guarded
START 1 SWITCH

ProSim System: Penumatic
ProSim Group: Switch
ProSim Config Names:
Start 1 Off
Start 1 GRD
Start 1 CONT
Start 1 FLT
Hardware:
Cole P/N 6600-2266 Magnetic Switch
Push in to rotate to GRD position; magnetic hold on GRD position
START 2 SWITCH

ProSim System: Penumatic
ProSim Group: Switch
ProSim Config Names:
Start 2 Off
Start 2 GRD
Start 2 CONT
Start 2 FLT
Hardware:
Cole P/N 6600-2266 Magnetic Switch
Push in to rotate to GRD position; magnetic hold on GRD position
STDBY RUD ON INDICATOR

ProSim System:
Hydraulic
ProSim Group:
Indicator
ProSim Config Names:
Stdby Rud On
Hardware:
Not Available
Notes:
Not Available
TAT TEST SWITCH

ProSim System: Heating
ProSim Group: Switch
ProSim Config Names:
TAT test Off
TAT test Pushed
Hardware:
Momentary push button, (ON)-OFF
TEMP PROBE HEAT INDICATOR

TR UNIT INDICATOR

TRANSFER BUS OFF 1 INDICATOR

TRANSFER BUS OFF 2 INDICATOR

TRIM AIR SWITCH

ProSim System: Pneumatic
ProSim Group: Switch
ProSim Config Names:
Trim air Off
Trim air On
Hardware:
Honeywell 1TL1-2D
2-POS ON-OFF
Locked in both positions
TRIP RESET SWITCH

ProSim System: Pneumatic
ProSim Group: Switch
ProSim Config Names:
Trip reset Off
Trip reset On
Hardware:
Momentary push button switch, (ON)-OFF
ProSim Config Names:
OVHT test Off
OVHT test On
VHF NAV SWITCH

ProSim System:
Navigation
ProSim Group:
Switch
ProSim Config Names:
VHF NAV Both on 1
VHF NAV Both on 2
XPDR ALT source 1
Hardware:
Not Available
Notes:
Not Available
WAI L VALVE OPEN INDICATOR

ProSim System: Heating
ProSim Group: Indicator
ProSim Config Names:
WAI L Valve Open
WAI L Valve Open bright (GATE)*
*This is a dual-brightness indicator. The bright state is a gate. Bright indicates the valve is in transit and dim indicates an full open state.
WAI R VALVE OPEN INDICATOR

ProSim System: Heating
ProSim Group: Indicator
ProSim Config Names:
WAI R Valve Open
WAI R Valve Open bright (GATE)*
*This is a dual-brightness indicator. The bright state is a gate. Bright indicates the valve is in transit and dim indicates an full open state.
WINDOW HEAT FWD L OVERHEAT INDICATOR

ProSim System: Heating
ProSim Group: Indicator
ProSim Config Names:
Window heat FWD L overheat
WINDOW HEAT SIDE L OVERHEAT INDICATOR

ProSim System: Heating
ProSim Group: Indicator
ProSim Config Names:
Window heat Side L overheat
WINDOW HEAT SIDE R OVERHEAT INDICATOR

ProSim System: Heating
ProSim Group: Indicator
ProSim Config Names:
Window heat Side R overheat
WINDOW HEAT FWD R OVERHEAT INDICATOR

ProSim System: Heating
ProSim Group: Indicator
ProSim Config Names:
Window heat FWD R overheat
WINDOW HEAT SIDE L INDICATOR

ProSim System: Heating
ProSim Group: Indicator
ProSim Config Names:
Window heat Side L off*
Window heat Side L on
*Not sure why this item is included. The ON item should be all that’s needed.
WINDOW HEAT FWD L INDICATOR

ProSim System: Heating
ProSim Group: Indicator
ProSim Config Names:
Window heat FWD L off*
Window heat FWD L on
*Not sure why this item is included. The ON item should be all that’s needed.
WINDOW HEAT FWD R INDICATOR

ProSim System: Heating
ProSim Group: Indicator
ProSim Config Names:
Window heat FWD R off*
Window heat FWD R on
*Not sure why this item is included. The ON item should be all that’s needed.
WINDOW HEAT SIDE R INDICATOR

ProSim System: Heating
ProSim Group: Indicator
ProSim Config Names:
Window heat Side R off*
Window heat Side R on
*Not sure why this item is included. The ON item should be all that’s needed.
WINDOW HEAT SIDE L SWITCH

ProSim System: Heating
ProSim Group: Switch
ProSim Config Names:
Window heat Side L Off
Window heat Side L On
Hardware:
Honeywell 1TL1-2
2-POS ON-OFF
WINDOW HEAT FWD L SWITCH

ProSim System: Heating
ProSim Group: Switch
ProSim Config Names:
Window heat FWD L Off
Window heat FWD L On
Hardware:
Honeywell 1TL1-2
2-POS ON-OFF
WINDOW HEAT TEST SWITCH

ProSim System: Heating
ProSim Group: Switch
ProSim Config Names:
Window heat test OVHT*
Window heat test Center
Window heat test PWR TEST*
*=Momentary position (Spring-loaded to Center)
Hardware:
Honeywell 1TL1-7
3-POS (ON)-OFF-(ON)
WINDOW HEAT FWD R SWITCH

ProSim System: Heating
ProSim Group: Switch
ProSim Config Names:
Window heat FWD R Off
Window heat FWD R On
Hardware:
Honeywell 1TL1-2
2-POS ON-OFF
WINDOW HEAT SIDE R SWITCH

ProSim System: Heating
ProSim Group: Switch
ProSim Config Names:
Window heat Side R Off
Window heat Side R On
Hardware:
Honeywell 1TL1-2
2-POS ON-OFF
WING ANTI-ICE SWITCH

ProSim System: Heating
ProSim Group: Switch
ProSim Config Names:
Wing Anti-Ice Off
Wing Anti-Ice On
Wing Anti-Ice hold actuator (GATE)*
Wing Anti-Ice off actuator (GATE)*
*This is a magnetic locking switch. When the magnet is powered by activating the gate, the magnet holds the switch in the ON position.
Hardware:
Microswitch 25ET61-S, Magnetic 28V
2-POS ON-OFF
(alternate Honeywell 1TL1-2 non-magnetic)
WING-BODY OVERHEAT 1 INDICATOR

ProSim System: Pneumatic
ProSim Group: Indicator
ProSim Config Names:
Wing-body overheat 1
WING-BODY OVERHEAT 2 INDICATOR

ProSim System: Pneumatic
ProSim Group: Indicator
ProSim Config Names:
Wing-body overheat 2
WIPER LEFT SWITCH

ProSim System: Misc
ProSim Group: Switch
ProSim Config Names:
Wiper left Park
Wiper left Int
Wiper left Low
Wiper left High
Hardware:
8-Position Rotary Switch (locked to 4 positions)
WIPER RIGHT SWITCH

ProSim System: Misc
ProSim Group: Switch
ProSim Config Names:
Wiper right Park
Wiper right Int
Wiper right Low
Wiper right High
Hardware:
8-Position Rotary Switch (locked to 4)
YAW DAMPER INDICATOR

ProSim System:
Misc
ProSim Group:
Indicator
ProSim Config Names:
Yaw damper
Hardware:
Not Available
Notes:
Not Available
YAW DAMPER SWITCH

ProSim System:
Misc
ProSim Group:
Switch
ProSim Config Names:
Yaw damper Off
Yaw damper On
Hardware:
25ET61-S
Notes:
Magnetic hold toggle switch. Holds in ON position when 28V DC power applied.
ZONE TEMP CONT CAB INDICATOR

ZONE TEMP FWD CAB INDICATOR

ZONE TEMP AFT CAB INDICATOR

VOICE RECORDER SWITCH
ProSim System: Misc
ProSim Group: Switch
ProSim Config Names:
Voice recorder Auto
Voice recorder On
Hardware:2-POS ON-OFF
VOICE RECORDER ERASE SWITCH
ProSim System: Misc
ProSim Group: Switch
ProSim Config Names:
Voice recorder erase Off
Voice recorder erase Pushed
Hardware: Momentary Push-button Switch
VOICE RECORDER TEST SWITCH
ProSim System: Misc
ProSim Group: Switch
ProSim Config Names:
Voice recorder test Off
Voice recorder test Pushed
Hardware: Momentary Push-Button Switch
VOICE RECORDER STATUS INDICATOR
ProSim System: Misc
ProSim Group: Indicator
ProSim Config Names:
Voice recorder status
Aft Overhead (AFT-OH)
AFT-OH
Click an item in the diagram at right to view its basic ProSim Config properties.
Click the More Info button that appears in this panel to visit the Combined Config reference table where you’ll find more detailed information on the item, if available.

ELT SWITCH

ProSim System: Misc
ProSim Group: Switch
ProSim Config Names:
ELT Arm
ELT On
Hardware:
2-POS ON-OFF
IRS DISP SEL SWITCH

ProSim System: Navigation
ProSim Group: Switch
ProSim Config Names:
IRS Disp Sel TK/GS
IRS Disp Sel Test
IRS Disp Sel PPOS
IRS Disp Sel Wind
IRS Disp Sel HDG/STS
Hardware:
12-POS Rotary Switch, 30 degree detents
IRS SYS DSPL SWITCH

ProSim System: Navigation
ProSim Group: Switch
ProSim Config Names:
IRS SYS DSPL Left
IRS SYS DSPL Right
Hardware:
8-POS rotary switch, limited to 2 positions
LE DEVICES INDICATORS

ProSim System: Misc
ProSim Group: Indicator
ProSim Config Names:
Flaps extended 1
Flaps extended 2
Flaps extended 3
Flaps extended 4
Flaps transit 1
Flaps transit 2
Flaps transit 3
Flaps transit 4
Slats extended 1
Slats extended 2
Slats extended 3
Slats extended 4
Slats extended 5
Slats extended 6
Slats extended 7
Slats extended 8
Slats fullExtended 1
Slats fullExtended 2
Slats fullExtended 3
Slats fullExtended 4
Slats fullExtended 5
Slats fullExtended 6
Slats fullExtended 7
Slats fullExtended 8
Slats transit 1
Slats transit 2
Slats transit 3
Slats transit 4
Slats transit 5
Slats transit 6
Slats transit 7
Slats transit 8
IRS KEYPAD SWITCHES

ProSim System: Navigation
ProSim Group: Switch
ProSim Config Names:
IRS Keypad 0 Off
IRS Keypad 0 Pushed
IRS Keypad 1 Off
IRS Keypad 1 Pushed
IRS Keypad 2 Off
IRS Keypad 2 Pushed
IRS Keypad 3 Off
IRS Keypad 3 Pushed
IRS Keypad 4 Off
IRS Keypad 4 Pushed
IRS Keypad 5 Off
IRS Keypad 5 Pushed
IRS Keypad 6 Off
IRS Keypad 6 Pushed
IRS Keypad 7 Off
IRS Keypad 7 Pushed
IRS Keypad 8 Off
IRS Keypad 8 Pushed
IRS Keypad 9 Off
IRS Keypad 9 Pushed
IRS Keypad CLR Off
IRS Keypad CLR Pushed
IRS Keypad ENT Off
IRS Keypad ENT Pushed
LE DEVICES TEST SWITCH

ProSim System: Misc
ProSim Group: Switch
ProSim Config Names:
LE Devices test Off
LE Devices test Pushed
Hardware:
Momentary push button, (ON)-OFF
IRS LEFT ALIGN INDICATOR

IRS RIGHT ALIGN INDICATOR

IRS LEFT ON DC INDICATOR

IRS RIGHT ON DC INDICATOR

IRS LEFT FAULT INDICATOR

IRS RIGHT FAULT INDICATOR

IRS LEFT DC FAIL INDICATOR

IRS RIGHT DC FAIL INDICATOR

IRS LEFT SWITCH

ProSim System: Navigation
ProSim Group: Switch
ProSim Config Names:
IRS left Nav
IRS left Off
IRS left Align
IRS left Att
Hardware:
IRS RIGHT SWITCH

ProSim System: Navigation
ProSim Group: Switch
ProSim Config Names:
IRS right Nav
IRS right Off
IRS right Align
IRS right Att
Hardware:
PSEU INDICATOR

DOME LIGHT SWITCH

ProSim System: Lighting
ProSim Group: Switch
ProSim Config Names:
Dome light Dim
Dome light Off
Dome light Bright
Domelight bright (GATE)
Domelight dim (GATE)
Domelight master (GATE)
Hardware:
3-POS toggle switch, ON-OFF-ON
REVERSER LEFT INDICATOR

REVERSER RIGHT INDICATOR

ENGINE CONTROL LEFT INDICATOR

ENGINE CONTROL RIGHT INDICATOR

EEC LEFT

ProSim System: Engine
ProSim Group: Indicator & Switch
ProSim Config Names:
EEC left Off (SWITCH)
EEC left Pushed (SWITCH)
EEC left latch Off (SWITCH)
EEC left latch On (SWITCH)
EEC Altn left (INDICATOR)
EEC On left (INDICATOR)
Hardware:
This is a specialized switch/indicator combination. The indicators and switch are controlled via multiple inputs on the back-side of the switch housing. FlightDeck Solutions makes the one I have.
EEC RIGHT

ProSim System: Engine
ProSim Group: Indicator & Switch
ProSim Config Names:
EEC right Off (SWITCH)
EEC right Pushed (SWITCH)
EEC right latch Off (SWITCH)
EEC right latch On (SWITCH)
EEC Altn right (INDICATOR)
EEC On right (INDICATOR)
Hardware:
This is a specialized switch/indicator combination. The indicators and switch are controlled via multiple inputs on the back-side of the switch housing. FlightDeck Solutions makes the one I have.
OXYGEN PRESSURE GAUGE

GEAR LEFT AFT OVH INDICATOR

ProSim System: Landing Gear
ProSim Group: Indicator
ProSim Config Names:
Gear left aft ovh
GEAR RIGHT AFT OVH INDICATOR

ProSim System: Landing Gear
ProSim Group: Indicator
ProSim Config Names:
Gear right aft ovh
GEAR NOSE AFT OVH INDICATOR

ProSim System: Landing Gear
ProSim Group: Indicator
ProSim Config Names:
Gear nose aft ovh
PASS OXY ON INDICATOR

PASS OXYGEN SWITCH

ProSim System: Pneumatic
ProSim Group: Switch
ProSim Config Names:
Pass oxygen Normal
Pass oxygen On
Hardware:
2-POS ON-OFF guarded toggle switch
Switch is in the NORMAL position when guarded.
FLIGHT RECORDER SWITCH

ProSim System: Misc
ProSim Group: Switch
ProSim Config Names:
Flight recorder Normal
Flight recorder Test
Hardware:
2-POS ON-OFF guarded toggle switch
Switch is in the Normal position when guard is closed.
FLIGHT RECORDER OFF INDICATOR

MACH AIRSPEED WARNING TEST NO1 SWITCH

ProSim System: Misc
ProSim Group: Switch
ProSim Config Names:
Mach Airspeed warning test no1 Off
Mach Airspeed warning test no1 Pushed
Hardware:
Momentary push button, (ON)-OFF
MACH AIRSPEED WARNING TEST NO2 SWITCH

ProSim System: Misc
ProSim Group: Switch
ProSim Config Names:
Mach Airspeed warning test no2 Off
Mach Airspeed warning test no2 Pushed
Hardware:
Momentary push button, (ON)-OFF
STALL TEST 1 SWITCH

ProSim System: Misc
ProSim Group: Switch
ProSim Config Names:
Stall test 1 Off
Stall test 1 Pushed
Hardware:
Momentary push button, (ON)-OFF
STALL TEST 2 SWITCH

ProSim System: Misc
ProSim Group: Switch
ProSim Config Names:
Stall test 2 Off
Stall test 2 Pushed
Hardware:
Momentary push button, (ON)-OFF
IRS DISPLAY LCD

ProSim System: Navigation
ProSim Group: LCD
ProSim Config Names:
IRS Display
IRS Display left char state (NUMERICAL)
IRS Display left mode (NUMERICAL)
IRS Display left number (NUMERICAL)
IRS Display right char state (NUMERICAL)
IRS Display right mode (NUMERICAL)
IRS Display right number (NUMERICAL)
ILS INDICATOR
ProSim System: Misc
ProSim Group: Indicator
ProSim Config Names:
ILS
GLS INDICATOR
ProSim System: Misc
ProSim Group: Indicator
ProSim Config Names:
GLS
ASP OBS PANEL
ProSim System: Communication
ProSim Group: Switch / Indicator / Analog
ProSim Config Names:
Too many items to list here. Click the More Info link to go to the detailed config items.
Main Instrument Panel – Captain (MIP-CAPT)
MIP-CAPT
Click an item in the diagram at right to view its basic ProSim Config properties.
Click the More Info button that appears in this panel to visit the Combined Config reference table where you’ll find more detailed information on the item, if available.

BELOW G/S P-INHIBIT INDICATOR
NOSE WHEEL STEERING SWITCH
ProSim System: Landing Gear
ProSim Group: Switch
ProSim Config Names:
Nose wheel steering Normal
Nose wheel steering Alternate
MAIN PANEL DUS SWITCH
ProSim System: MIP
ProSim Group: Switch
ProSim Config Names:
Main Panel DUs Capt Norm
Main Panel DUs Capt Outbd PFD
Main Panel DUs Capt Eng Pri
Main Panel DUs Capt PFD
Main Panel DUs Capt MFD
LOWER DU CAPT SWITCH
ProSim System: MIP
ProSim Group: Switch
ProSim Config Names:
Lower DU Capt Norm
Lower DU Capt ND
Lower DU Capt Eng Pri
CHRONO CAPT CHR SWITCH

ProSim System: MIP
ProSim Group: Switch
ProSim Config Names:
Chrono capt CHR Normal
Chrono capt CHR Pushed
CHRONO CAPT DATE/TIME SWITCH

ProSim System: MIP
ProSim Group: Switch
ProSim Config Names:
Chrono capt Date/Time Normal
Chrono capt Date/Time Pushed
CHRONO CAPT SET SWITCH

ProSim System: MIP
ProSim Group: Switch
ProSim Config Names:
Chrono capt SET Normal
Chrono capt SET Pushed
CHRONO CAPT + SWITCH

ProSim System: MIP
ProSim Group: Switch
ProSim Config Names:
Chrono capt + Normal
Chrono capt + Pushed
CHRONO CAPT – SWITCH

ProSim System: MIP
ProSim Group: Switch
ProSim Config Names:
Chrono capt – Normal
Chrono capt – Pushed
CHRONO CAPT RESET SWITCH

ProSim System: MIP
ProSim Group: Switch
ProSim Config Names:
Chrono capt RESET Normal
Chrono capt RESET Pushed
CHRONO CAPT ET SWITCH

ProSim System: MIP
ProSim Group: Switch
ProSim Config Names:
Chrono capt ET Normal
Chrono capt ET Pushed
CHRONO CAPT ALTERNATE CONTROL

ProSim System: MIP
ProSim Group: Switch
ProSim Config Names:
Chrono capt alternate control Run
Chrono capt alternate control Hold
Chrono capt alternate control Reset
Notes:
This rotary switch is used on the older style Chronos as pictured.
CAPT ASA A/P INDICATOR
ProSim System: MIP
ProSim Group: Indicator
ProSim Config Names:
ASA A/P Amber Capt
ASA A/P Red Capt
CAPT ASA A/P RESET SWITCH
ProSim System: MIP
ProSim Group: Switch
ProSim Config Names:
ASA A/P reset Capt Off
ASA A/P reset Capt Pushed
CAPT ASA A/T INDICATOR
ProSim System: MIP
ProSim Group: Indicator
ProSim Config Names:
ASA A/T Amber Capt
ASA A/T Red Capt
CAPT ASA A/T RESET SWITCH
ProSim System: MIP
ProSim Group: Switch
ProSim Config Names:
ASA A/T reset Capt Off
ASA A/T reset Capt Pushed
CAPT ASA FMC INDICATOR
CAPT ASA FMC RESET SWITCH
ProSim System: MIP
ProSim Group: Switch
ProSim Config Names:
ASA FMC reset Capt Off
ASA FMC reset Capt Pushed
SPEEDBRAKE ARMED INDICATOR
SPEEDBRAKE DO NOT ARM INDICATOR
STAB OUT OF TRIM INDICATOR
STAB OUT OF TRIM SWITCH
ProSim System: MIP
ProSim Group: Switch
ProSim Config Names:
Stab out of trim PTT Normal
Stab out of trim PTT Pushed
CAPT ASA TEST SWITCH
ProSim System: MIP
ProSim Group: Switch
ProSim Config Names:
ASA Test Capt Off
ASA Test Capt 1
ASA Test Capt 2
LIGHT TEST SWITCH
ProSim System: Lighting
ProSim Group: Switch
ProSim Config Names:
Light Test Bright
Light Test Dim
Light Test Test
UPPER DU BRIGHTNESS KNOB
LEFT OUTBOARD DU BRIGHTNESS KNOB
LEFT INBOARD BRIGHTNESS (OUTER KNOB)
- MIP
- Left Inboard Brightness (Analog)
- Not Available
- Not Available
LEFT INBOARD BRIGHTNESS (INNER KNOB)
- MIP
- Left Inboard Brightness Inner (Analog)
- Not Available
- Not Available
LOWER DU BRIGHTNESS (OUTER KNOB)
- MIP
- Lower DU Brightness (Analog)
- Not Available
- Not Available
LOWER DU BRIGHTNESS (INNER KNOB)
- MIP
- Lower DU Brightness Inner (Analog)
- Not Available
- Not Available
MCP BACKGROUND LIGHT KNOB
ProSim System: Lighting
ProSim Group: Analog / Numerical
ProSim Config Names:
MCP background light (Analog)
MCP background light output (Numerical)
AFDS FLOOD LIGHT KNOB
ProSim System: Lighting
ProSim Group: Analog / Numerical
ProSim Config Names:
AFDS flood light (Analog)
AFDS flood light output (Numerical)
MAIN PANEL BRIGHTNESS KNOB
ProSim System: Lighting
ProSim Group: Analog / Numerical
ProSim Config Names:
Panel lights (Analog)
Panel lights output (Numerical)
Main Instrument Panel – Center (MIP-CENTER)
MIP-CENTER

AUTO BRAKE DISARM INDICATOR
ProSim System
- Landing Gear
Config Name (Group)
- Autobrake disarm (Indicator)
- Autobrake disarm PTT Normal (Switch)
- Autobrake disarm PTT Pushed (Switch)
Hardware
- Not Available
Notes
- Not Available
ANTI SKID INOP INDICATOR
ProSim System
- Landing Gear
Config Name (Group)
- Anti skid INOP (Indicator)
- Anti skid INOP PTT Normal (Switch)
- Anti skid INOP PTT Pushed (Switch)
Hardware
- Not Available
Notes
- Not Available
AUTOBRAKE SWITCH
ProSim System
- Landing Gear
Config Name (Group)
- Autobrake Off (Switch)
- Autobrake RTO (Switch)
- Autobrake 1 (Switch)
- Autobrake 2 (Switch)
- Autobrake 3 (Switch)
- Autobrake Max (Switch)
- Autobrake reset (Gate)
Notes
- Not Available
FLAPS GAUGE
ProSim System
- MIP
Config Names (Groups)
- Flap (Gauge)
Hardware
- Not Available
Notes
- Not Available
FUEL FLOW SWITCH
ProSim System
- MIP
Config Names (Groups)
- Fuel flow Rate (Switch)
- Fuel flow Used (Switch)
- Fuel flow Reset (Switch)
Hardware
- Not Available
Notes
- Not Available
ISFD APP SWITCH
ProSim System
- MIP
Config Names (Groups)
- ISFD APP Off (Switch)
- ISFD APP Pushed (Switch)
Hardware
- Momentary pushbutton switch
Notes
- Not Available
ISFD HP/IN SWITCH
ProSim System
- MIP
Config Names (Groups)
- ISFD HP/IN Off (Switch)
- ISFD HP/IN Pushed (Switch)
Hardware
- Momentary pushbutton switch
Notes
- Not Available
ISFD + SWITCH
ProSim System
- MIP
Config Names (Groups)
- ISFD + Off (Switch)
- ISFD + Pushed (Switch)
Hardware
- Momentary pushbutton switch
Notes
- Not Available
ISFD – SWITCH
ProSim System
- MIP
Config Names (Groups)
- ISFD – Off (Switch)
- ISFD – Pushed (Switch)
Hardware
- Momentary pushbutton switch
Notes
- Not Available
ISFD RST SWITCH
ProSim System
- MIP
Config Names (Groups)
- ISFD RST Off (Switch)
- ISFD RST Pushed (Switch)
Hardware
- Momentary pushbutton switch
Notes
- Not Available
ISFD BARO KNOB
ProSim System
- MIP
Config Names (Groups)
- ISFD baro STD Off (Switch)
- ISFD baro STD Pushed (Switch)
- ISFD baro encoder pulse down Off (Encoder)
- ISFD baro encoder pulse down On (Encoder)
- ISFD baro encoder pulse up Off (Encoder)
- ISFD baro encoder pulse up On (Encoder)
Hardware
- Not Available
Notes
- Not Available
LE FLAPS EXT INDICATOR
ProSim System
- MIP
Config Name (Group)
- LE Flap Extend (Indicator)
- LE Flap Extend PTT Normal (Switch)
- LE Flap Extend PTT Pushed (Switch)
Hardware
-
- Not Available
Notes
- Not Available
LE FLAPS TRANSIT INDICATOR
ProSim System
- MIP
Config Name (Group)
- LE Flap Transit (Indicator)
- LE Flap Transit PTT Normal (Switch)
- LE Flap Transit PTT Pushed (Switch)
Hardware
- Not Available
Notes
- Not Available
MFD SYS SWITCH
ProSim System
- MIP
Config Names (Groups)
- MFD SYS Normal (Switch)
- MFD SYS Pushed (Switch)
Hardware
- Momentary pushbutton switch.
Notes
- Note, does not light up in normal or depressed state.
MFD ENG SWITCH
ProSim System
- MIP
Config Names (Groups)
- MFD ENG Normal (Switch)
- MFD ENG Pushed (Switch)
Hardware
- Momentary pushbutton switch.
Notes
- Note, does not light up in normal or depressed state.
N1 SET SWITCH (OUTER KNOB)
ProSim System
- MIP
Config Names (Groups)
- N1 SET AUTO (Switch)
- N1 SET 1 (Switch)
- N1 SET 2 (Switch)
- N1 SET Both (Switch)
Hardware
- Dual concentric knobs. Outer is a 4 position rotary switch, inner is a momentary spring-loaded to center switch (or an encoder)
Notes
- Not Available
N1 SET ROTARY (INNER KNOB)
ProSim System
- MIP
Config Names (Groups)
- N1 SET Rotary (Encoder)
- N1 SET Rotary momentary Center (Switch)
- N1 SET Rotary momentary Up (Switch)
- N1 SET Rotary momentary Down (Switch)
- N1 SET Rotary momentary Upfast (Switch)
- N1 SET Rotary momentary Downfast (Switch)
- N1 SET Rotary pulse down Off (Switch)
- N1 SET Rotary pulse down On (Switch)
- N1 SET Rotary pulse up Off (Switch)
- N1 SET Rotary pulse up On (Switch)
Hardware
- Dual concentric knobs. Outer is a 4 position rotary switch, inner is a momentary spring-loaded to center switch (or an encoder)
Notes
- Not Available
SPEED REF SWITCH (OUTER KNOB)
- MIP
- SPD REF AUTO (Switch)
- SPD REF V1 (Switch)
- SPD REF VR (Switch)
- SPD REF WT (Switch)
- SPD REF VREF (Switch)
- SPD REF BUG (Switch)
- Dual concentric knobs. Outer knob is an 8-position Rotary Switch. Inner knob is a momentary spring-loaded to center switch (or encoder).
- Not Available
SPD REF ROTARY (INNER KNOB)
- MIP
- SPD REF Rotary (Encoder)
- SPD REF SET (Switch)
- SPD REF Rotary momentary Center (Switch)
- SPD REF Rotary momentary Up (Switch)
- SPD REF Rotary momentary Down (Switch)
- SPD REF Rotary momentary Up fast (Switch)
- SPD REF Rotary momentary Down fast (Switch)
- SPD REF Rotary pulse down Off (Switch)
- SPD REF Rotary pulse down On (Switch)
- SPD REF Rotary pulse up Off (Switch)
- SPD REF Rotary pulse up On (Switch)
- Dual concentric knobs. Outer knob is an 8-position Rotary Switch. Inner knob is a momentary spring-loaded to center switch (or encoder).
- Not Available
STANDBY RMI NAV1 SWITCH
ProSim System
- MIP
Config Names (Groups)
- Standby RMI NAV1 mode VOR (Switch)
- Standby RMI NAV1 mode ADF (Switch)
- Standby RMI NAV1 mode F/O VOR (Switch)
- Standby RMI NAV1 mode F/O ADF (Switch)
Hardware
- Not Available
Notes
- Not Available
STANDBY RMI NAV2 SWITCH
ProSim System
- MIP
Config Names (Groups)
- Standby RMI NAV2 mode VOR (Switch)
- Standby RMI NAV2 mode ADF (Switch)
- Standby RMI NAV2 mode F/O VOR (Switch)
- Standby RMI NAV2 mode F/O ADF (Switch)
Hardware
- Not Available
Notes
- Not Available
YAW DAMPER GAUGE
ProSim System
- MIP
Config Names (Groups)
- Yaw damper gauge (Gauge)
Hardware
- Not Available
Notes
- Not available
Main Instrument Panel – First Officer (MIP-FO)
MIP-FO
Click an item in the diagram at right to view its basic ProSim Config properties.
Click the More Info button that appears in this panel to visit the Combined Config reference table where you’ll find more detailed information on the item, if available.

NOSE GEAR TRANSIT INDICATOR
- Landing Gear
- Gear nose transit (Indicator)
- Gear nose PTT Normal (Switch)
- Gear nose PTT Pushed (Switch)
- Not Available
- Not Available
ASA LIGHT TEST SWITCH
- MIP
- ASA Test F/O Off (Switch)
- ASA Test F/O 1 (Switch)
- ASA Test F/O 2 (Switch)
- Momentary switch, spring-loaded to center.
- Not Available
BELOW G/S P/INHIBIT INDICATOR
- MIP
- Below GS FO (Indicator)
- Not Available
- Not Available
BRAKE PRESSURE GAUGE
- Hydraulic
- Brake pressure (Gauge)
- Not Available
- Not Available
F/O AUTOTHROTTLE RESET INDICATOR
- MIP
- ASA A/T Amber F/O (Indicator)
- ASA A/T Red F/O (Indicator)
- ASA A/T reset Capt Off (Switch)
- ASA A/T reset Capt Pushed (Switch)
- Not Available
- Not Available
F/O AUTOPILOT RESET INDICATOR
- MIP
- ASA A/P Amber F/O (Indicator)
- ASA A/P Red F/O (Indicator)
- ASA A/P reset F/O Off (Switch)
- ASA A/P reset F/O Pushed (Switch)
- Not Available
- Not Available
F/O CABIN ALTITUDE INDICATOR
- MIP
- Cabin altitude indicator FO (Indicator)
- Cabin altitude indicator FO PTT Normal (Switch)
- Cabin altitude indicator FO PTT Pushed (Switch)
- Not Available
- Not Available
F/O CHRONO ET SWITCH
- MIP
- Chrono f/o ET Normal (Switch)
- Chrono f/o ET Pushed (Switch)
- Not Available
- Not Available
F/O CHRONO PLUS SWITCH
- MIP
- Chrono f/o + Normal (Switch)
- Chrono f/o + Pushed (Switch)
- Not Available
- Not Available
F/O CHRONO RESET SWITCH
- MIP
- Chrono f/o RESET Normal (Switch)
- Chrono f/o RESET Pushed (Switch)
- Not Available
- Not Available
F/O CHRONO SET SWITCH
- MIP
- Chrono f/o SET Normal (Switch)
- Chrono f/o SET Pushed (Switch)
- Not Available
- Not Available
F/O CHRONO CHR SWITCH
- MIP
- Chrono f/o CHR Normal (Switch)
- Chrono f/o CHR Pushed (Switch)
- Not Available
- Not Available
F/O CHRONO MINUS SWITCH
- MIP
- Chrono f/o – Normal (Switch)
- Chrono f/o – Pushed (Switch)
- Not Available
- Not Available
F/O CHRONO TIME/DATE SWITCH
- MIP
- Chrono f/o Date/Time Normal (Switch)
- Chrono f/o Date/Time Pushed (Switch)
- Not Available
- Not Available
F/O FMC RESET INDICATOR
- MIP
- ASA FMC F/O (Indicator)
- ASA FMC reset F/O Off (Switch)
- ASA FMC reset F/O Pushed (Switch)
- Not Available
- Not Available
F/O TAKEOFF CONFIG INDICATOR
- MIP
- Takeoff config FO (Indicator)
- Takeoff config FO PTT Normal (Switch)
- Takeoff config FO PTT Pushed (Switch)
- Not Available
- Not Available
FLAP INBHIBIT SWITCH
- MIP
- Flap inhibit Norm (Switch)
- Flap inhibit inhibit (Switch)
- Not Available
- Not Available
FLAP LOAD RELIEF INDICATOR
- MIP
- Flap load relief (Indicator)
- Flap load relief PTT Normal (Switch)
- Flap load relief PTT Pushed (Switch)
- Not Available
- Not Available
GEAR INHIBIT SWITCH
- MIP
- Gear inhibit Norm (Switch)
- Gear inhibit Inhibit (Switch)
- Not Available
- Not Available
GPWS INOP INDICATOR
- MIP
- GPWS lnop (Indicator)
- GPWS lnop PTT Normal (Switch)
- GPWS lnop PTT Pushed (Switch)
- Not Available
- Not Available
GPWS SYS TEST
- MIP
- GPWS Sys test Off (Switch)
- GPWS Sys test Pushed (Switch)
- Not Available
- Not Available
INBOARD DU BRIGHTNESS (OUTER KNOB)
- MIP
- Right Inboard Brightness (Analog)
- Not Available
- Not Available
LANDING GEAR LEVER
- Landing Gear
- Gear Off (Switch)
- Gear Up (Switch)
- Gear Down (Switch)
- Not Available
- Not Available
LEFT GEAR TRANSIT INDICATOR
- Landing Gear
- Gear left transit (Indicator)
- Gear left transit PTT Normal (Switch)
- Gear left transit PTT Pushed (Switch)
- Not Available
- Not Available
LEFT GEAR DOWN INDICATOR
- Landing Gear
- Gear left (Indicator)
- Gear left PTT Normal (Switch)
- Gear left PTT Pushed (Switch)
- Not Available
- Not Available
LOWER DU FO SWITCH
- MIP
- Lower DU FO Norm (Switch)
- Lower DU FO ND (Switch)
- Lower DU FO Eng Pri (Switch)
- 8-position rotary limited to three positions.
- Not Available
MAIN PANEL BRIGHTNESS KNOB
- Lighting
- MIP panel fo light (Analog)
- Not Available
- Not Available
MAIN PANEL DUS FO SWITCH
- MIP
- Main Panel DUs FO Norm (Switch)
- Main Panel DUs FO Outbd PFD (Switch)
- Main Panel DUs FO Eng Pri (Switch)
- Main Panel DUs FO PFD (Switch)
- Main Panel DUs FO MFD (Switch)
- 8-position rotary limited to 5 positions.
- Not Available
NOSE GEAR DOWN INDCATOR
- Landing Gear
- Gear nose (Indicator)
- Gear nose PTT Normal (Switch)
- Gear nose PTT Pushed (Switch)
- Not Available
- Not Available
OUTBOARD DU BRIGHTNESS KNOB
- MIP
- Right Outboard Brightness (Analog)
- Not Available
- Not Available
RIGHT GEAR TRANSIT INDICATOR
- Landing Gear
- Gear right transit (Indicator)
- Gear right transit PTT Normal (Switch)
- Gear right transit PTT Pushed (Switch)
- Not Available
- Not Available
RIGHT GEAR DOWN INDICATOR
- Landing Gear
- Gear right (Indicator)
- Gear right PTT Normal (Switch)
- Gear right PTT Pushed (Switch)
- Not Available
- Not Available
SPEED BRAKES EXTENDED INDICATOR
- MIP
- Spoiler Extend (Indicator)
- Spoiler Extend PTT Normal (Switch)
- Spoiler Extend PTT Pushed (Switch)
- Not Available
- Not Available
TERRAIN INHIBIT SWITCH
- MIP
- Terrain inhibit Norm (Switch)
- Terrain inhibit Inhibit (Switch)
- Not Available
- Not Available
INBOARD DU BRIGHTNESS (INNER KNOB)
- MIP
- Right Inboard Brightness Inner (Analog)
- Not Available
- Not Available
Mode Control Panel (MCP)
MCP
Click an item in the diagram at right to view its basic ProSim Config properties.
Click the More Info button that appears in this panel to visit the Combined Config reference table where you’ll find more detailed information on the item, if available.

COURSE 1 KNOB
- Throttle/MCP
- MCP COURSE 1 VAL (Analog)
- MCP COURSE 1 VAL encoder (Encoder)
- MCP V/S VAL (Analog)
- Speedbrake input (Analog)
- Throttle input left (Analog)
- Throttle input right (Analog)
- Not Available
- Not Available
COURSE 1 DISPLAY
- Throttle/MCP
- MCP COURSE 1 VAL output (Numerical)
- Not Available
- Not Available
CAPT F/D SWITCH
- Throttle/MCP
- MCP Captain F/D Off (Switch)
- MCP Captain F/D On (Switch)
- Not Available
- Not Available
A/T ARM INDICATOR
- Throttle/MCP
- MCP A/T (Indicator)
- Not Available
- Not Available
A/T SWITCH
- Throttle/MCP
- MCP Captain F/D Off (Switch)
- MCP Captain F/D On (Switch)
- Not Available
- Not Available
CAPTAIN MASTER F/D INDICATOR
- Throttle/MCP
- MCP FCC A Master (Indicator)
- Not Available
- Not Available
N1 SWITCH/INDICATOR
- Throttle/MCP
- MCP N1 Off (Switch)
- MCP N1 Pushed (Switch)
- MCP N1 (Indicator)
- Not Available
- Not Available
SPD SWITCH/INDICATOR
- Throttle/MCP
- MCP Speed hold Off (Switch)
- MCP Speed hold Pushed (Switch)
- MCP Speed (Indicator)
- Not Available
- Not Available
C/O SWITCH
- Throttle/MCP
- MCP C/O Off (Switch)
- MCP C/O Pushed (Switch)
- Not Available
- Not Available
IAS/MACH SELECTOR KNOB
- Throttle/MCP
- MCP SPEED VAL (Analog)
- MCP SPEED VAL encoder (Encoder)
- MCP SPEED VAL encoder pulse down Off (Switch)
- MCP SPEED VAL encoder pulse down On (Switch)
- MCP SPEED VAL encoder pulse up Off (Switch)
- MCP SPEED VAL encoder pulse up On (Switch)
- Not Available
- Not Available
SPD INTV SWITCH
- Throttle/MCP
- MCP Speed Int Pushed (Switch)
- MCP Speed hold Off (Switch)
- Not Available
- Not Available
IAS/MACH DISPLAY
- Throttle/MCP
- MCP SPEED VAL output (Numerical)
- Not Available
- Not Available
VNAV SWITCH/INDICATOR
- Throttle/MCP
- MCP VNAV Off (Switch)
- MCP VNAV Pushed (Switch)
- MCP VNAV (Indicator)
- Not Available
- Not Available
LVL CHG SWITCH/INDICATOR
- Throttle/MCP
- MCP Level change Off (Switch)
- MCP Level change Pushed (Switch)
- MCP Level Change (Indicator)
- Not Available
- Not Available
BANK SELECT (OUTER KNOB)
- Throttle/MCP
- MCP Bank limit 10 (Switch)
- MCP Bank llmit 15 (Switch)
- MCP Bank limit 20 (Switch)
- MCP Bank limit 25 (Switch)
- MCP Bank limit 30 (Switch)
- Not Available
- Not Available
HEADING SELECT (INNER KNOB)
- Throttle/MCP
- MCP HEADING VAL (Analog)
- MCP HEADING VAL encoder (Encoder)
- MCP HEADING VAL encoder pulse down Off (Switch)
- MCP HEADING VAL encoder pulse down On (Switch)
- MCP HEADING VAL encoder pulse up Off (Switch)
- MCP HEADING VAL encoder pulse up On (Switch)
- Not Available
- Not Available
HDG SEL SWITCH/INDICATOR
- Throttle/MCP
- MCP Heading sel Off (Switch)
- MCP Heading sel Pushed (Switch)
- MCP HDG SEL (Indicator)
- Not Available
- Not Available
HEADING DISPLAY
- Throttle/MCP
- MCP HEADING VAL output (Numerical)
- Not Available
- Not Available
LNAV SWITCH/INDICATOR
- Throttle/MCP
- MCP LNAV Off (Switch)
- MCP LNAV Pushed (Switch)
- MCP LNAV (Indicator)
- Not Available
- Not Available
VOR LOC SWITCH/INDICATOR
- Throttle/MCP
- MCP VOR/LOC Off (Switch)
- MCP VOR/LOC Pushed (Switch)
- MCP VOR/LOC (Indicator)
- Not Available
- Not Available
APP SWITCH/INDICATOR
- Throttle/MCP
- MCP APP Off (Switch)
- MCP APP Pushed (Switch)
- MCP APP (Indicator)
- Not Available
- Not Available
ALT HLD SWITCH/INDICATOR
- Throttle/MCP
- MCP Alt hold Off (Switch)
- MCP Alt hold Pushed (Switch)
- MCP Alt hold (Indicator)
- Not Available
- Not Available
ALTITUDE DISPLAY
- Throttle/MCP
- MCP ALT VAL output (Numerical)
- Not Available
- Not Available
ALT INTV SWITCH
- Throttle/MCP
- MCP Alt Int Off (Switch)
- MCP Alt Int Pushed (Switch)
- Not Available
- Not Available
V/S SWITCH/INDICATOR
- Throttle/MCP
- MCP V/S Off (Switch)
- MCP V/S Pushed (Switch)
- MCP V/S (Indicator)
- Not Available
- Not Available
AUTOPILOT DISENGAGE SWITCH
- Throttle/MCP
- MCP AP Disengage Normal (Switch)
- MCP AP Disengage Disengage (Switch)
- Not Available
- Not Available
CMD A SWITCH/INDICATOR
- Throttle/MCP
- MCP CMD A Off (Switch)
- MCP CMD A Pushed (Switch)
- MCP CMD A (Indicator)
- Not Available
- Not Available
CMD B SWITCH/INDICATOR
- Throttle/MCP
- MCP CMD B Off (Switch)
- MCP CMD B Pushed (Switch)
- MCP CMD B (Indicator)
- Not Available
- Not Available
CWS A SWITCH/INDICATOR
- Throttle/MCP
- MCP CWS A Off (Switch)
- MCP CWS A Pushed (Switch)
- MCP CWS A (Indicator)
- Not Available
- Not Available
CWS B SWITCH/INDICATOR
- Throttle/MCP
- MCP CWS B Off (Switch)
- MCP CWS B Pushed (Switch)
- MCP CWS B (Indicator)
- Not Available
- Not Available
VERTICAL SPEED THUMBWHEEL
- Throttle/MCP
- MCP V/S VAL (Analog)
- MCP V/S VAL encoder (Encoder)
- MCP V/S VAL encoder pulse down Off (Switch)
- MCP V/S VAL encoder pulse down On (Switch)
- MCP V/S VAL encoder pulse up Off (Switch)
- MCP V/S VAL encoder pulse up On (Switch)
- Not Available
- Not Available
VERT SPEED DISPLAY
- Throttle/MCP
- MCP V/S VAL output (Numerical)
- Not Available
- Not Available
FO F/D SWITCH
- Throttle/MCP
- MCP F/O F/D Off (Switch)
- MCP F/O FD Pushed (Switch)
- Not Available
- Not Available
COURSE KNOB 2
- Throttle/MCP
- MCP COURSE 2 VAL (Analog)
- MCP COURSE 2 VAL encoder (Encoder)
- MCP COURSE 2 VAL encoder pulse down Off (Switch)
- MCP COURSE 2 VAL encoder pulse down On (Switch)
- MCP COURSE 2 VAL encoder pulse up Off (Switch)
- MCP COURSE 2 VAL encoder pulse up On (Switch)
- Not Available
- Not Available
COURSE 2 DISPLAY
- Throttle/MCP
- MCP COURSE 2 VAL output (Numerical)
- Not Available
- Not Available
FO MASTER F/D INDICATOR
- Throttle/MCP
- MCP FCC B Master (Indicator)
- Not Available
- Not Available
ALTITUDE SELECT KNOB
- Throttle/MCP
- MCP ALT VAL (Analog)
- MCP ALT VAL encoder (Encoder)
- MCP ALT VAL encoder pulse down Off (Switch)
- MCP ALT VAL encoder pulse down On (Switch)
- MCP ALT VAL encoder pulse up Off (Switch)
- MCP ALT VAL encoder pulse up On (Switch)
- Not Available
- Not Available
Electronic Flight Instrument System (EFIS)
EFIS
Click an item in the diagram at right to view its basic ProSim Config properties.
Click the More Info button that appears in this panel to visit the Combined Config reference table where you’ll find more detailed information on the item, if available.

EFIS 1 WXR SWITCH
- Throttle/MCP
- EFIS 1 WXR Off (Switch)
- EFIS 1 WXR Pushed (Switch)
- Not Available
- Not Available
EFIS 1 STA SWITCH
- Throttle/MCP
- EFIS 1 STA Off (Switch)
- EFIS 1 STA Pushed (Switch)
- Not Available
- Not Available
EFIS 1 WPT SWITCH
- Throttle/MCP
- EFIS 1 WPT Off (Switch)
- EFIS 1 WPT Pushed (Switch)
- Not Available
- Not Available
EFIS 1 ARPT SWITCH
- Throttle/MCP
- EFIS 1 ARPT Off (Switch)
- EFIS 1 ARPT Pushed (Switch)
- Not Available
- Not Available
EFIS 1 DATA SWITCH
- Throttle/MCP
- EFIS 1 DATA Off (Switch)
- EFIS 1 DATA Pushed (Switch)
- Not Available
- Not Available
EFIS 1 POS SWITCH
- Throttle/MCP
- EFIS 1 POS Off (Switch)
- EFIS 1 POS Pushed (Switch)
- Not Available
- Not Available
EFIS 1 TERR SWITCH
- Throttle/MCP
- EFIS 1 TERR Off (Switch)
- EFIS 1 TERR Pushed (Switch)
- Not Available
- Not Available
EFIS 1 SELECTOR 1 SWITCH
- Throttle/MCP
- EFIS 1 Selector 1 OFF (Switch)
- EFIS 1 Selector 1 VOR 1 (Switch)
- EFIS 1 Selector 1 ADF 1 (Switch)
- Not Available
- Not Available
EFIS 1 SELECTOR 2 SWITCH
- Throttle/MCP
- EFIS 1 Selector 2 OFF (Switch)
- EFIS 1 Selector 2 VOR 2 (Switch)
- EFIS 1 Selector 2 ADF 2 (Switch)
- Not Available
- Not Available
EFIS 1 MODE SWITCH
- Throttle/MCP
- EFIS 1 Mode APP (Switch)
- EFIS 1 Mode VOR (Switch)
- EFIS 1 Mode MAP (Switch)
- EFIS 1 Mode PLN (Switch)
- Not Available
- Not Available
EFIS 1 CTR SWITCH
- Throttle/MCP
- EFIS 1 CTR Off (Switch)
- EFIS 1 CTR Pushed (Switch)
- Not Available
- Not Available
EFIS 1 RANGE SWITCH
- Throttle/MCP
- EFIS 1 Range 5 (Switch)
- EFIS 1 Range 10 (Switch)
- EFIS 1 Range 20 (Switch)
- EFIS 1 Range 40 (Switch)
- EFIS 1 Range 80 (Switch)
- EFIS 1 Range 160 (Switch)
- EFIS 1 Range 320 (Switch)
- EFIS 1 Range 640 (Switch)
- Not Available
- Not Available
EFIS 1 TFC SWITCH
- Throttle/MCP
- EFIS 1 TFC Off (Switch)
- EFIS 1 TFC Pushed (Switch)
- Not Available
- Not Available
EFIS 1 MINS SELECTOR (OUTER KNOB)
- Throttle/MCP
- EFIS 1 Minimums mode Radio (Switch)
- EFIS 1 Minimums mode Baro (Switch)
- Not Available
- Not Available
EFIS 1 MINS SELECTOR (INNER KNOB)
- Throttle/MCP
- EFIS 1 minimums (Encoder)
- EFIS 1 minimums momentary Center (Switch)
- EFIS 1 minimums momentary Up (Switch)
- EFIS 1 minimums momentary Down (Switch)
- EFIS 1 minimums momentary Upfast (Switch)
- EFIS 1 minimums momentary Downfast (Switch)
- EFIS 1 minimums pulse down Off (Switch)
- EFIS 1 minimums pulse down On (Switch)
- EFIS 1 minimums pulse up Off (Switch)
- EFIS 1 minimums pulse up On (Switch)
- Not Available
- Not Available
EFIS 1 MINS RST SWITCH
- Throttle/MCP
- EFIS 1 MINS Reset Off (Switch)
- EFIS 1 MINS Reset Pushed (Switch)
- Not Available
- Not Available
EFIS 1 FPV SWITCH
- Throttle/MCP
- EFIS 1 FPV Off (Switch)
- EFIS 1 FPV Pushed (Switch)
- Not Available
- Not Available
EFIS 1 MTRS SWITCH
- Throttle/MCP
- EFIS 1 MTRS Off (Switch)
- EFIS 1 MTRS Pushed (Switch)
- Not Available
- Not Available
EFIS 1 BARO SELECTOR (OUTER KNOB)
- Throttle/MCP
- EFIS 1 Baro mode Inch (Switch)
- EFIS 1 Baro mode HPa (Switch)
- Not Available
- Not Available
EFIS 1 BARO SELECTOR (INNER KNOB)
- Throttle/MCP
- EFIS 1 baro (Encoder)
- EFIS 1 baro momentary Center (Switch)
- EFIS 1 baro momentary Up (Switch)
- EFIS 1 baro momentary Down (Switch)
- EFIS 1 baro momentary Up fast (Switch)
- EFIS 1 baro momentary Down fast (Switch)
- EFIS 1 baro pulse down Off (Switch)
- EFIS 1 baro pulse down On (Switch)
- EFIS 1 baro pulse up Off (Switch)
- EFIS 1 baro pulse up On (Switch)
- Not Available
- Not Available
EFIS 1 STD SWITCH
- Throttle/MCP
- EFIS 1 Baro STD Off (Switch)
- EFIS 1 Baro STD Pushed (Switch)
- Not Available
- Not Available
EFIS 2 WXR SWITCH
- Throttle/MCP
- EFIS 2 WXR Off (Switch)
- EFIS 2 WXR Pushed (Switch)
- Not Available
- Not Available
EFIS 2 STA SWITCH
- Throttle/MCP
- EFIS 2 STA Off (Switch)
- EFIS 2 STA Pushed (Switch)
- Not Available
- Not Available
EFIS 2 WPT SWITCH
- Throttle/MCP
- EFIS 2 WPT Off (Switch)
- EFIS 2 WPT Pushed (Switch)
- Not Available
- Not Available
EFIS2 ARPT SWITCH
- Throttle/MCP
- EFIS 2 ARPT Off (Switch)
- EFIS 2 ARPT Pushed (Switch)
- Not Available
- Not Available
EFIS 2 DATA SWITCH
- Throttle/MCP
- EFIS 2 DATA Off (Switch)
- EFIS 2 DATA Pushed (Switch)
- Not Available
- Not Available
EFIS 2 POS SWITCH
- Throttle/MCP
- EFIS 2 POS Off (Switch)
- EFIS 2 POS Pushed (Switch)
- Not Available
- Not Available
EFIS 2 TERR SWITCH
- Throttle/MCP
- EFIS 2 TERR Off (Switch)
- EFIS 2 TERR Pushed (Switch)
- Not Available
- Not Available
EFIS 2 SELECTOR 1 SWITCH
- Throttle/MCP
- EFIS 2 Selector 1 OFF (Switch)
- EFIS 2 Selector 1 VOR 1 (Switch)
- EFIS 2 Selector 1 ADF 1 (Switch)
- Not Available
- Not Available
EFIS 2 SELECTOR 2 SWITCH
- Throttle/MCP
- EFIS 2 Selector 2 OFF (Switch)
- EFIS 2 Selector 2 VOR 2 (Switch)
- EFIS 2 Selector 2 ADF 2 (Switch)
- Not Available
- Not Available
EFIS 2 MODE SWITCH
- Throttle/MCP
- EFIS 2 Mode APP (Switch)
- EFIS 2 Mode VOR (Switch)
- EFIS 2 Mode MAP (Switch)
- EFIS 2 Mode PLN (Switch)
- Not Available
- Not Available
EFIS 2 CTR SWITCH
- Throttle/MCP
- EFIS 2 CTR Off (Switch)
- EFIS 2 CTR Pushed (Switch)
- Not Available
- Not Available
EFIS 2 RANGE SWITCH
- Throttle/MCP
- EFIS 2 Range 5 (Switch)
- EFIS 2 Range 10 (Switch)
- EFIS 2 Range 20 (Switch)
- EFIS 2 Range 40 (Switch)
- EFIS 2 Range 80 (Switch)
- EFIS 2 Range 160 (Switch)
- EFIS 2 Range 320 (Switch)
- EFIS 2 Range 640 (Switch)
- Not Available
- Not Available
EFIS 2 TFC SWITCH
- Throttle/MCP
- EFIS 2 TFC Off (Switch)
- EFIS 2 TFC Pushed (Switch)
- Not Available
- Not Available
EFIS 2 MINS SELECTOR (OUTER KNOB)
- Throttle/MCP
- EFIS 2 Minimums mode Radio (Switch)
- EFIS 2 Minimums mode Baro (Switch)
- Not Available
- Not Available
Glare Wings
Glare
Click an item in the diagram at right to view its basic ProSim Config properties.
Click the More Info button that appears in this panel to visit the Combined Config reference table where you’ll find more detailed information on the item, if available.

FIRE WARNING 1 INDICATOR/SWITCH
- Warning
- Fire warning 1 (Indicator)
- Fire warning 1 Off (Switch)
- Fire warning 1 Pushed (Switch)
- Not Available
- Not Available
MASTER CAUTION 1 INDICATOR/SWITCH
- Warning
- Master caution 1 (Indicator)
- Master caution 1 off (Switch)
- Master caution 1 Pushed (Switch)
- Not Available
- Not Available
RECALL 1 INDICATORS/SWITCH
- Warning
- Recall 1 Off (Switch)
- Recall 1 Pushed (Switch)
- Warn FLT_CONT (Indicator)
- Warrn ELEC (Indicator)
- Warn IRS (Indicator)
- Warn APU (Indicator)
- Warn FUEL (Indicator)
- Warn OVHT_DET (Indicator)
- Not Available
- Not Available
RECALL 2 INDICATORS/SWITCH
- Warning
- Recall 2 Off (Switch)
- Recall 2 Pushed (Switch)
- Warn ANTI_ICE (Indicator)
- Warn ENG (Indicator)
- Warn HYD (Indicator)
- Warn OVERHEAD (Indicator)
- Warn DOORS (Indicator)
- Warn AIR_COND (Indicator)
- Not Available
- Not Available
MASTER CAUTION 2 INDICATOR/SWITCH
- Warning
- Master caution 2 (Indicator)
- Master caution 2 Off (Switch)
- Master caution 2 Pushed (Switch)
- Not Available
- Not Available
FIRE WARNING 2 INDICATOR/SWITCH
- Warning
- Fire warning 2 (Indicator)
- Fire warning 2 off (Switch)
- Fire warning 2 Pushed (Switch)
- Not Available
- Not Available
Computer Display Units (CDU), Throttle Quadrant (TQ), and Center Pedestal
CDU-TQ-Pedestal
Click an item in the diagram at right to view its basic ProSim Config properties.
Click the More Info button that appears in this panel to visit the Combined Config reference table where you’ll find more detailed information on the item, if available.
