A visual reference for all configurable items within the ProSimB738 Combined Config menu.
This page is a work in progress.
INSTRUCTIONS: Scroll down to the panel drawings and click on a highlighted button, switch, knob or indicator to activate the information panel on the left side. It will tell you what ProSim Config Items are associated with that particular hardware item. Clicking the More Info button that appears in the left panel will take you to a searchable Lookup Table of config items, filtered by that item. Or, you can click the Switch to Lookup Table button below to go to the lookup table directly and search there.
Sincere appreciation to Cockpit Revolution for generously providing the high quality drawings used on this page.
(Note: Some drawings may be slightly altered from author’s originals to accommodate Pro-Sim’s configuration layout)
Table of contents
- Forward Overhead (FWD-OH)
- Aft Overhead (AFT-OH)
- Main Instrument Panel – Captain (MIP-CAPT)
- Main Instrument Panel – Center (MIP-CENTER)
- Main Instrument Panel – First Officer (MIP-FO)
- Mode Control Panel (MCP)
- Electronic Flight Instrument System (EFIS)
- Glare Wings
- Computer Display Units (CDU), Throttle Quadrant (TQ), and Center Pedestal
Forward Overhead (FWD-OH)
FWD-OH
Click an item in the diagram at right to view its basic ProSim Config properties.
Click the More Info button that appears in this panel to visit the Combined Config reference table where you’ll find more detailed information on the item, if available.
APU GEN 1 SWITCH
ProSim System: Electric
ProSim Group: Switch
ProSim Config Names:
APU GEN 1 Off*
APU GEN 1 Center
APU GEN 1 On*
*=Momentary
Hardware:
Honeywell 1TL1-7E
3-POS (ON) OFF (ON)
Center-Locking
Spring-loaded to Center position
AFT CAB SELECTOR
ProSim System: Pneumatic
ProSim Group: Analog
ProSim Config Names:
AFT CAB selector
Hardware:
10K Potentiometer
ALPHA VANE HEAT L INDICATOR
ALPHA VANE HEAT R INDICATOR
ProSim System: Heating
ProSim Group: Indicator
ProSim Config Names:
Alpha Vane Heat R*
*The ProSim virtual panel shows the indicator incorrectly as “L ALPHA VANE”. It should be “R ALPHA VANE” as per the real aircraft.
ALT HORN CUTOUT SWITCH
ProSim System: Penumatic
ProSim Group: Switch
ProSim Config Names:
Alt horn cutout Off
Alt horn cutout Pushed
Hardware:
Momentary push button, (ON)-OFF
ALTERNATE FLAPS CTRL SWITCH
ProSim System:
Hydraulic
ProSim Group:
Switch
ProSim Config Names:
Alternate flaps ctrl Off
Alternate flaps ctrl Up
Alternate flaps ctrl Down
Hardware:
Honeywell 1TL1-5
Notes:
3-POS ON-OFF-(ON).
UP position – indexed
OFF position – indexed
DOWN position – Momentary ON
Normal position is OFF.
Make sure you orient the switch accordingly.
ALTERNATE FLAPS SWITCH
ProSim System:
Hydraulic
ProSim Group:
Switch
ProSim Config Names:
Alternate flaps Off
Alternate flaps Arm
Hardware:
Honeywell 1TL1-2
Notes:
2-POS ON-OFF
Switch is in OFF position when guard is closed. You do not need to assign the OFF switch position in ProSim Config.
APU FAULT INDICATOR
APU GEN 2 SWITCH
ProSim System: Electric
ProSim Group: Switch
ProSim Config Names:
APU GEN 2 Off*
APU GEN 2 Center
APU GEN 2 On*
*=Momentary
Hardware:
Honeywell 1TL1-7E
3-POS (ON) OFF (ON)
Center-Locking
Spring-loaded to Center position
APU GEN OFF BUS INDICATOR
APU LOW OIL PRESSURE INDICATOR
APU MAINT INDICATOR
APU OVERSPEED INDICATOR
APU SWITCH
ProSim System: Electric
ProSim Group: Switch
ProSim Config Names:
APU Switch Off
APU Switch On
APU Switch Start*
*=Momentary
Hardware:
Honeywell 1TL1-5K
3-POS ON-OFF-(ON)
Spring-loaded from Start to On
ATTEND SWITCH
ProSim System: Misc
ProSim Group: Switch
ProSim Config Names:
Attend Off
Attend Pushed
Hardware:
Momentary push-button, (ON)-OFF
AUTO SLAT FAIL INDICATOR
ProSim System: Flight Controls
ProSim Group: Indicator
ProSim Config Names:
Auto slat Fail
Hardware:
Notes:
AUX PITOT HEAT INDICATOR
BAT DISCHARGE INDICATOR
BATTERY SWITCH
ProSim System: Electric
ProSim Group: Switch
ProSim Config Names:
Battery switch Off
Battery switch On
Hardware:
Honeywell 1TL1-2
Guarded 2-POS ON-OFF
In On position when guarded
BLEED 1 SWITCH
ProSim System: Pneumatic
ProSim Group: Switch
ProSim Config Names:
Bleed 1 Off
Bleed 1 On
Hardware:
Honeywell 1TL1-2D
2-POS ON-OFF
Locked in both positions
BLEED 2 SWITCH
ProSim System: Pneumatic
ProSim Group: Switch
ProSim Config Names:
Bleed 2 Off
Bleed 2 On
Hardware:
Honeywell 1TL1-2D
2-POS ON-OFF
Locked in both positions
BLEED APU SWITCH
ProSim System: Pneumatic
ProSim Group: Switch
ProSim Config Names:
Bleed APU Off
Bleed APU On
Hardware:
Honeywell 1TL1-2D
2-POS ON-OFF
Locked in both positions
BLEED TRIP OFF 1 INDICATOR
BLEED TRIP OFF 2 INDICATOR
BUS TRANSFER SWITCH
ProSim System: Electric
ProSim Group: Switch
ProSim Config Names:
Bus transfer switch Off
Bus transfer switch Auto
Hardware:
Honeywell 1TL1-1
Guarded 2-POS ON-OFF
In Auto position when guarded
CABIN TEMP SELECTOR SWITCH
ProSim System: Misc
ProSim Group: Indicator
ProSim Config Names:
Air Temp Selector CONT CAB
Air Temp Selector DUCT FWD
Air Temp Selector DUCT AFT
Air Temp Selector CAB FWD
Air Temp Selector CAB AFT
Air Temp Selector R
Air Temp Selector L
Hardware:
8-Position Rotary Switch
CABIN TEMPERATURE GAUGE
CABIN VSI GAUGE
CALL INDICATOR
CAPT PITOT HEAT INDICATOR
CONT CAB SELECTOR
ProSim System: Pneumatic
ProSim Group: Analog
ProSim Config Names:
CONT CAB selector
Hardware:
10K Potentiometer
COPILOT PITOT HEAT INDICATOR
ProSim System: Heating
ProSim Group: Indicator
ProSim Config Names:
Copilot Pitot Heat*
*NOTE: This is the correct item name for the “F/O PITOT” indicator
COWL ANTI-ICE L INDICATOR
COWL ANTI-ICE R INDICATOR
COWL VALVE OPEN L INDICATOR
ProSim System: Heating
ProSim Group: Indicator
ProSim Config Names:
Cowl valve open L
Cowl valve open L bright (GATE)*
*This is a dual-brightness indicator. The bright state is activated by a gate. Bright indicates the valve is in transit and dim indicates a full open state.
COWL VALVE OPEN R INDICATOR
ProSim System: Heating
ProSim Group: Indicator
ProSim Config Names:
Cowl valve open R
Cowl valve open R bright (GATE)*
*This is a dual-brightness indicator. The bright state is activated by a gate. Bright indicates the valve is in transit and dim indicates a full open state.
CROSSFEED INDICATOR
ProSim System: Fuel
ProSim Group: Indicator
ProSim Config Names:
Crossfeed indicator
Crossfeed indicator bright
This is a dual-brightness indicator
CROSSFEED SWITCH
ProSim System: Fuel
ProSim Group: Switch
ProSim Config Names:
Crossfeed Off
Crossfeed On
Hardware:
Honeywell 7AS12
90 Degree 2-POS Rotary
Knob P/N BP073-109
DISCONNECT 1 SWITCH
ProSim System: Electric
ProSim Group: Switch
ProSim Config Names:
Disconnect 1 Normal
Disconnect 1 Off
Hardware:
Honeywell 1TL1-2
Guarded 2-POS ON-OFF
In Normal position when guarded
DISCONNECT 2 SWITCH
ProSim System: Electric
ProSim Group: Switch
ProSim Config Names:
Disconnect 2 Normal
Disconnect 2 Off
Hardware:
Honeywell 1TL1-2
Guarded 2-POS ON-OFF
In Normal position when guarded
DISPLAY CONTROL PANEL SWITCH
ProSim System: Misc
ProSim Group: Switch
ProSim Config Names:
Display Control Panel Both on 1
Display Control Panel Normal
Display Control Panel Both on 2
DISPLAY SOURCE SWITCH
ProSim System: Misc
ProSim Group: Switch
ProSim Config Names:
Display source All on 1
Display source Auto
Display source All on 2
Hardware:
8 Position Rotary (restricted to 3 positions)
DOOR AFT CARGO INDICATOR
DOOR AFT ENTRY INDICATOR
DOOR AFT SERVICE INDICATOR
DOOR AIR STAIRS INDICATOR
DOOR EQUIP INDICATOR
DOOR FWD CARGO INDICATOR
DOOR FWD ENTRY INDICATOR
DOOR FWD SERVICE INDICATOR
DOOR LEFT AFT OVERWING INDICATOR
DOOR LEFT FWD OVERWING INDICATOR
DOOR RIGHT AFT OVERWING INDICATOR
DOOR RIGHT FWD OVERWING INDICATOR
DRIVE 1 INDICATOR
DRIVE 2 INDICATOR
DUAL BLEED INDICATOR
ELEC MAINT SWITCH
ProSim System: Electric
ProSim Group: Switch
ProSim Config Names:
Elec maint Off
Elec maint Pushed
Hardware:
Momentary push button, (ON)-OFF
ELEC PNL AC SWITCH
ProSim System: Electric
ProSim Group: Switch
ProSim Config Names:
Elec Pnl AC STBY PWR
Elec Pnl AC GRD PWR
Elec Pnl AC GEN1
Elec Pnl AC APU GEN
Elec Pnl AC GEN2
Elec Pnl AC INV
Elec Pnl AC TEST
Hardware:
8 Position Rotary Switch
(restricted to 7 positions)
ELEC PNL DC SWITCH
ProSim System: Electric
ProSim System: Switch
ProSim Config Names:
Elec Pnl DC STBY PWR
Elec Pnl DC BAT BUS
Elec Pnl DC BAT
Elec Pnl DC AUX BAT
Elec Pnl DC TR1
Elec Pnl DC TR2
Elec Pnl DC TR3
Elec Pnl DC TEST
Hardware:
8 Position Rotary Switch
ELECTRIC PANEL LCD
ELEV PITOT HEAT L INDICATOR
ELEV PITOT HEAT R INDICATOR
EMER EXIT LIGHTS SWITCH
ProSim System: Lighting
ProSim Group: Switch
ProSim Config Names:
Emer Exit Light Off
Emer Exit Lights Armed
Emer Exit Lights On
ON position is the active state when guard is closed.
Hardware:
Honeywell ITL1-1
3-POS ON-OFF-ON
EMERG EXIT LIGHTS NOT ARMED INDICATOR
ProSim System: Lighting
ProSim Group: Indicator
ProSim Config Names:
Emerg Exit Lights not armed
ENG ANTI-ICE 1 SWITCH
ProSim System: Heating
ProSim Group: Switch
ProSim Config Names:
Eng Anti-Ice 1 Off
Eng Anti-Ice 1 On
Hardware:
Honeywell 1TL1-2D
2-POS ON-OFF
Locked in both positions
ENG ANTI-ICE 2 SWITCH
ProSim System: Heating
ProSim Group: Switch
ProSim Config Names:
Eng Anti-Ice 2 Off
Eng Anti-Ice 2 On
Hardware:
Honeywell 1TL1-2D
2-POS ON-OFF
Locked in both positions
ENG VALVE CLOSED L INDICATOR
ProSim System: Fuel
ProSim Group: Indicator
ProSim Config Names:
ENG Valve Closed L
ENG Valve Closed L bright
This is a dual-brightness indicator
ENG VALVE CLOSED R INDICATOR
ProSim System: Fuel
ProSim Group: Indicator
ProSim Config Names:
ENG Valve Closed R
ENG Valve Closed R bright
This is a dual-brightness indicator
EQUIP COOLING EXAUST OFF INDICATOR
ProSim System: Misc
ProSim Group: Indicator
ProSim Config Names:
Equip cooling exhaust Off
EQUIP COOLING EXAUST SWITCH
ProSim System: Misc
ProSim Group: Switch
ProSim Config Names:
Equip cooling exhaust Normal
Equip cooling exhaust Alternate
Hardware:
Honeywell 1TL1-2
2-POS ON-OFF
EQUIP COOLING SUPPLY OFF INDICATOR
EQUIP COOLING SUPPLY SWITCH
ProSim System: Misc
ProSim Group: Switch
ProSim Config Names:
Equip cooling supply Normal
Equip cooling supply Alternate
Hardware:
Honeywell 1TL1-2
2-POS ON-OFF
FEEL DIFF PRESS INDICATOR
ProSim System: Hydraulic
ProSim Group: Indicator
ProSim Config Names:
Feel Diff Press
Hardware:
Notes:
FILTER BYPASS L INDICATOR
FILTER BYPASS R INDICATOR
FLT ALT DISPLAY
FLT CTRL A SWITCH
ProSim System:
Hydraulic
ProSim Group:
Switch
ProSim Config Names:
Flt Ctrl A Off
Flt Ctrl A Stby Rud
Flt Ctrl A A On
Hardware:
Honeywell 1TL1-1
Notes:
3-POS ON-OFF-ON
You do not need to assign the OFF position to ProSim.
Associate one ON switch position to the STBY RUD and then assign to ProSim Config item “Flt Ctrl A Stby Rud”.
Associate the other ON switch position to the A ON and then assign to ProSim Config item “Flt Ctrl A A On”.
FLT CTRL B SWITCH
ProSim System:
Hydraulic
ProSim Group:
Switch
ProSim Config Names:
Flt Ctrl B Off
Flt Ctrl B Stby Rud
Flt Ctrl B B On
Hardware:
Honeywell 1TL1-1
Notes:
3-POS ON-OFF-ON
You do not need to assign the OFF position to ProSim.
Associate one ON switch position to the STBY RUD and then assign to ProSim Config item “Flt Ctrl B Stby Rud”.
Associate the other ON switch position to the A ON and then assign to ProSim Config item “Flt Ctrl B B On”.
FLT CONTROL LOW PRESSURE A INDICATOR
ProSim System:
Hydraulic
ProSim Group:
Indicator
ProSim Config Names:
FLT Control low pressure A
Hardware:
N/A
Notes:
None
FLT CONTROL LOW PRESSURE B INDICATOR
ProSim System:
Hydraulic
ProSim Group:
Indicator
ProSim Config Names:
FLT Control low pressure B
Hardware:
N/A
Notes:
None
FLIGHT ALT ENCODER
ProSim System: Pneumatic
ProSim Group: Encoder
ProSim Config Names:
Flight alt in encoder
NOTE: other related inputs include:
Flight alt in encoder pulse down Off (SWITCH)
Flight alt in encoder pulse down On (SWITCH)
Flight alt in encoder pulse up Off (SWITCH)
Flight alt in encoder pulse up On (SWITCH)
Flight alt in (ANALOG)
Hardware:
Continuous rotary encoder switch
FMC SWITCH
ProSim System: Navigation
ProSim Group: Switch
ProSim Config Names:
FMC Normal
FMC Both on L
FMC Both on R
Hardware:
Honeywell 1TL1-1A
3-POS ON-OFF-ON
Locking in all three positions
FUEL CENTER LEFT LP INDICATOR
FUEL CENTER LEFT SWITCH
ProSim System: Fuel
ProSim Group: Switch
ProSim Config Names:
Fuel Center Left Off
Fuel Center Left On
Hardware:
Honeywell 1TL1-2D
2-POS ON-OFF
Locked in both positions
FUEL CENTER RIGHT LP INDICATOR
FUEL CENTER RIGHT SWITCH
ProSim System: Fuel
ProSim Group: Switch
ProSim Config Names:
Fuel Center Right Off
Fuel Center Right On
Hardware:
Honeywell 1TL1-2D
2-POS ON-OFF
Locked in both positions
FUEL LEFT AFT LP INDICATOR
FUEL LEFT AFT SWITCH
ProSim System: Fuel
ProSim Group: Switch
ProSim Config Names:
Fuel Left Aft Off
Fuel Left Aft On
Hardware:
Honeywell 1TL1-2D
2-POS ON-OFF
Locked in both positions
FUEL LEFT FWD LP INDICATOR
FUEL LEFT FWD SWITCH
ProSim System: Fuel
ProSim Group: Switch
ProSim Config Names:
Fuel Left Fwd Off
Fuel Left Fwd On
Hardware:
Honeywell 1TL1-2D
2-POS ON-OFF
Locked in both positions
FUEL RIGHT FWD SWITCH
ProSim System: Fuel
ProSim Group: Switch
ProSim Config Names:
Fuel Right Fwd Off
Fuel Right Fwd On
Hardware:
Honeywell 1TL1-2D
2-POS ON-OFF
Locked in both positions
FUEL RIGHT AFT LP INDICATOR
FUEL RIGHT AFT SWITCH
ProSim System: Fuel
ProSim Group: Switch
ProSim Config Names:
Fuel Right Aft Off
Fuel Right Aft On
Hardware:
Honeywell 1TL1-2D
2-POS ON-OFF
Locked in both positions
FUEL RIGHT FWD LP INDICATOR
FUEL TEMPERATURE GAUGE
FWD CAB SELECTOR
ProSim System: Pneumatic
ProSim Group: Analog
ProSim Config Names:
FWD CAB selector
Hardware:
10K Potentiometer
GALLEY SWITCH
ProSim System: Electric
ProSim Group: Switch
ProSim Config Names:
Galley Off
Galley On
Hardware:
Honeywell 1TL12
2-POS ON-OFF
GEN OFF BUS 1 INDICATOR
GEN OFF BUS 2 INDICATOR
GEN 1 SWITCH
ProSim System: Electric
ProSim Group: Switch
ProSim Config Names:
GEN 1 Off*
GEN 1 Center
GEN 1 On*
*=Momentary
Hardware:Honeywell 1TL1-7E
3-POS (ON)-OFF-(ON)
Center-Locking
Spring-loaded to Center position
GEN 2 SWITCH
ProSim System: Electric
ProSim Group: Switch
ProSim Config Names:
GEN 2 Off*
GEN 2 Center
GEN 2 On*
*=Momentary
Hardware:
Honeywell 1TL1-7E
3-POS (ON)-OFF-(ON)
Center-Locking
Spring-loaded to Center position
GROUND CALL SWITCH
ProSim System: Misc
ProSim Group: Switch
ProSim Config Names:
Ground call Off
Ground call Pushed
Hardware:
Momentary push-button, (ON)-OFF
GROUND POWER AVAILABLE INDICATOR
GROUND POWER SWITCH
ProSim System: Electric
ProSim Group: Switch
ProSim Config Names:
Ground Power Off*
Ground Power Center
Ground Power On*
*=Momentary
Hardware:
Honeywell 1TL1-7E
3-POS (ON)-OFF-(ON)
Center-Locking
Spring-loaded to Center
HYD ELEC1 LP INDICATOR
HYD ELEC2 LP INDICATOR
HYD ELEC1 OVHT INDICATOR
HYD ELEC2 OVHT INDICATOR
HYD ELEC1 SWITCH
ProSim System: Hydraulic
ProSim Group: Switch
ProSim Config Names:
Hyd ELEC1 Off
Hyd ELEC1 On
Hardware:
Honeywell 1TL1-2D
2-POS ON-OFF
Locked in both positions
HYD ELEC2 SWITCH
ProSim System: Hydraulic
ProSim Group: Switch
ProSim Config Names:
Hyd ELEC2 Off
Hyd ELEC2 On
Hardware:
Honeywell 1TL1-2D
2-POS ON-OFF
Locked in both positions
HYD ENG1 LP INDICATOR
HYD ENG2 LP INDICATOR
HYD ENG1 SWITCH
ProSim System: Hydraulic
ProSim Group: Switch
ProSim Config Names:
Hyd ENG1 Off
Hyd ENG1 On
Hardware:
Honeywell 1TL1-2D
2-POS ON-OFF
Locked in both positions
HYD ENG2 SWITCH
ProSim System: Hydraulic
ProSim Group: Switch
ProSim Config Names:
Hyd ENG2 Off
Hyd ENG2 On
Hardware:
Honeywell 1TL1-2D
2-POS ON-OFF
Locked in both positions
HYD STANDBY LOW PRESSURE INDICATOR
ProSim System:
Hydraulic
ProSim Group:
Indicator
ProSim Config Names:
Hyd standby low pressure
Hardware:
N/A
Notes:
None
HYD STANDBY LOW QUANTITY INDICATOR
ProSim System:
Hydraulic
ProSim Group:
Indicator
ProSim Config Names:
Hyd standby low quantity
Hardware:
N/A
Notes:
None
IGNITION SELECT SWITCH
ProSim System: Electric
ProSim Group: Switch
ProSim Config Names:
Ignition select Both
Ignition select Left
Ignition select Right
Hardware:
Honeywell 1TL1-1
3-POS ON-OFF-ON
IRS SWITCH
ProSim System: Navigation
ProSim Group: Switch
ProSim Config Names:
IRS Normal
IRS Both on L
IRS Both on R
Hardware:
Honeywell 1TL1-1A
3-POS ON-OFF-ON
Locking in all three positions
LAND ALT ENCODER
ProSim System: Pneumatic
ProSim Group: Encoder
ProSim Config Names:
Land alt in encoder
NOTE: other related inputs include:
Land alt in encoder pulse down Off (SWITCH)
Land alt in encoder pulse down On (SWITCH)
Land alt (NUMERICAL)
Land alt in (ANALOG)
Hardware:
Continuous rotary encoder switch
LAVATORY SMOKE INDICATOR
LIGHT MAIN RETRACT SWITCHES
ProSim System: Lighting
ProSim Group: Switch
ProSim Config Names:
For 2-Position Variation:
Light Main Retract L On
Light Main Retract L Off
Light Main Retract R On
Light Main Retract R Off
For 3-Position Variation:
Light Main Retract L 3 POS Retracted
Light Main Retract L 3 POS Extended
Light Main Retract L 3 POS On
Light Main Retract R 3 POS Retracted
Light Main Retract R 3 POS Extended
Light Main Retract R 3 POS On
Hardware:
2-POS ON-OFF, Honeywell 1TL133-2
3-POS ON-OFF-ON, Honeywell 1TL133-1
LIGHT MAIN FIXED SWITCHES
ProSim System: Lighting
ProSim Group: Switch
ProSim Config Names:
Light Main Fixed L On
Light Main Fixed L Off
Light Main Fixed R On
Light Main Fixed R Off
Hardware:
Honeywell 1TL133-2
2-POS ON-OFF
LIGHTS ANTI COLLISION SWITCH
ProSim System: Lighting
ProSim Group: Switch
ProSim Config Names:
Lights Anti collision Off
Lights Anti collision On
Hardware:
Honeywell 1TL1-2
2-POS ON-OFF
LIGHTS LOGO SWITCH
ProSim System: Lighting
ProSim Group: Switch
ProSim Config Names:
Lights Logo Off
Lights Logo On
Hardware:
Honeywell 1TL1-2
2-POS ON-OFF
LIGHTS POSITION SWITCH
ProSim System: Lighting
ProSim Group: Switch
ProSim Config Names:
Lights Position Off
Lights Position On
Hardware:
Honeywell 1TL1-2
2-POS ON-OFF
NOTE: This is designed for the separate Strobe and Position switches. If your strobe light switch is a combined 3-position “Position Strobe & Steady”switch, use the Strobe switch config item instead and assign the 3 positions to it.
LIGHTS RUNWAY TURNOFF SWITCHES
ProSim System: Lighting
ProSim Group: Switch
ProSim Config Names:
Lights Runway turnoff L On
Lights Runway turnoff L Off
Lights Runway turnoff R On
Lights Runway turnoff R Off
Hardware:
Honeywell 1TL1-2
2-POS ON-OFF
LIGHTS STROBE SWITCH
ProSim System: Lighting
ProSim Group: Switch
ProSim Config Names:
2-POS:
Lights Strobe Off
Lights Strobe On
OR
3-POS:
Lights Strobe & Steady Strobe & Steady
Lights Strobe & Steady Off
Lights Strobe & Steady Steady
Hardware:
For 2-POS: Honeywell 1TL1-2 ON-OFF
For 3-POS: Honeywell 1TL1-1 ON-OFF-ON
LIGHTS TAXI SWITCH
ProSim System: Lighting
ProSim Group: Switch
ProSim Config Names:
Lights Taxi On
Lights Taxi Off
Hardware:
Honeywell 1TL1-2
2-POS ON-OFF
LIGHTS WHEEL WELL SWITCH
ProSim System: Lighting
ProSim Group: Switch
ProSim Config Names:
Lights Wheel well Off
Lights Wheel well On
Hardware:
Honeywell 1TL1-2
2-POS ON-OFF
LIGHTS WING SWITCH
ProSim System: Lighting
ProSim Group: Switch
ProSim Config Names:
Lights Wing Off
Lights Wing On
Hardware:
Honeywell 1TL1-2
2-POS ON-OFF
MACH TRIM FAIL INDICATOR
ProSim System: Misc
ProSim Group: Indicator
ProSim Config Names:
Mach Trim Fail
Hardware:
Notes:
NO SMOKING SWITCH
ProSim System: Misc
ProSim Group: Switch
ProSim Config Names:
No Smoking Off
No Smoking Auto
No Smoking On
Hardware:
Honeywell 1TL1-1
3-POS ON-OFF-ON
OFF SCHED DESCENT INDICATOR
OUTFLOW VALVE POSITION GAUGE
OUTFLOW VALVE SWITCH
ProSim System: Pneumatic
ProSim Group: Switch
ProSim Config Names:
Outflow valve Off
Outflow valve Open
Outflow valve Close
Hardware:
Honeywell 1TL1-7
3-POS (ON)-OFF-(ON)
OVHT TEST
ProSim System: Pneumatic
ProSim Group: Switch
ProSim Config Names:
OVHT test Off
OVHT test On
Hardware:
Momentary push button (ON)-OFF
PACK 1 SWITCH
ProSim System: Pneumatic
ProSim Group: Switch
ProSim Config Names:
Pack 1 Auto
Pack 1 High
Pack 1 Off
Hardware:
Honeywell 1TL1-1A
3-POS ON-OFF-ON
Locked in all 3 positions
PACK 2 SWITCH
ProSim System: Pneumatic
ProSim Group: Switch
ProSim Config Names:
Pack 1 Auto
Pack 1 High
Pack 1 Off
Hardware:
Honeywell 1TL1-1A
3-POS ON-OFF-ON
Locked in all 3 positions
PACK L INDICATOR
PACK R INDICATOR
PNEUMATIC ISOLATION SWITCH
ProSim System: Pneumatic
ProSim Group: Switch
ProSim Config Names:
Pneumatic Isolation switch Open
Pneumatic Isolation switch Auto
Pneumatic Isolation switch Close
Hardware:
Honeywell 1TL1-1A
3-POS ON-OFF-ON
Locked in all 3 positions
PRESSURE DIFFERENTIAL GAUGE
PRESSURE GAUGE
ProSim System: Pneumatic
ProSim Group: Gauge
ProSim Config Names:
Pressure Left
Pressure Right
PRESSURIZATION ALTN INDICATOR
PRESSURIZATION AUTO FAIL INDICATOR
ProSim System: Pneumatic
ProSim Group: Indicator
ProSim Config Names:
Pressurization auto fail
PRESSURIZATION MANUAL INDICATOR
ProSim System: Pneumatic
ProSim Group: Indicator
ProSim Config Names:
Pressurization manual
PRESSURIZATION SWITCH
ProSim System: Pneumatic
ProSim Group: Switch
ProSim Config Names:
Pressurization Auto
Pressurization Altn
Pressurization Man
Hardware:
8-POS rotary switch limited to 3 positions
PROBE HEAT A SWITCH
ProSim System: Heating
ProSim Group: Switch
ProSim Config Names:
Probe heat A OFF
Probe heat A ON
Hardware:
Honeywell 1TL1-w
2-POS ON-OFF
PROBE HEAT B SWITCH
ProSim System: Heating
ProSim Group: Switch
ProSim Config Names:
Probe heat B OFF
Probe heat B ON
Hardware:
Honeywell 1TL1-w
2-POS ON-OFF
RAM DOOR FULL OPEN L INDICATOR
ProSim System: Pneumatic
ProSim Group: Indicator
ProSim Config Names:
Ram door full open L
Ram door full open L bright (GATE)
RAM DOOR FULL OPEN R INDICATOR
ProSim System: Pneumatic
ProSim Group: Indicator
ProSim Config Names:
Ram door full open R
Ram door full open R bright (GATE)
RECIRC FAN L SWITCH
ProSim System: Pneumatic
ProSim Group: Switch
ProSim Config Names:
Recirc Fan L Auto
Recirc Fan L Off
Recirc Fan L running (GATE)
Hardware:
Honeywell 1TL1-2
2-POS ON-OFF
RECIRC FAN R SWITCH
ProSim System: Pneumatic
ProSim Group: Switch
ProSim Config Names:
Recirc Fan R Auto
Recirc Fan R Off
Recirc Fan R running (GATE)
Hardware:
Honeywell 1TL1-2
2-POS ON-OFF
SEATBELT SWITCH
ProSim System: Misc
ProSim Group: Switch
ProSim Config Names:
Seatbelt Off
Seatbelt Auto
Seatbelt On
Hardware:
Honeywell 1TL1-1
3-POS ON-OFF-ON
SOURCE OFF 1 INDICATOR
SOURCE OFF 2 INDICATOR
SPAR VALVE CLOSED L INDICATOR
ProSim System: Fuel
ProSim Group: Indicator
ProSim Config Names:
SPAR Valve Closed L
SPAR Valve Closed L bright
This is a dual-brightness indicator
SPAR VALVE CLOSED R INDICATOR
ProSim System: Fuel
ProSim Group: Indicator
ProSim Config Names:
SPAR Valve Closed R
SPAR Valve Closed R bright
This is a dual-brightness indicator
SPEED TRIM FAIL INDICATOR
ProSim System: Flight Controls
ProSim Group: Indicator
ProSim Config Names:
Speed Trim Fail
Hardware:
Notes:
SPOILER A SWITCH
ProSim System: Hydraulic
ProSim Group: Switch
ProSim Config Names:
Spoiler A Off
Spoiler A On
Hardware:
Honeywell 1TL1-2
Notes:
2 Position, ON-OFF
SPOILER B SWITCH
ProSim System: Hydraulic
ProSim Group: Switch
ProSim Config Names:
Spoiler B Off
Spoiler B On
Hardware:
Honeywell 1TL1-2
Notes:
2-Position, ON-OFF
STANDBY POWER OFF INDICATOR
STANDBY POWER SWITCH
ProSim System: Electric
ProSim Group: Switch
ProSim Config Names:
Standby power switch Off
Standby power switch Bat
Standby power switch Auto
Hardware:
Honeywell 1TL1-1
3-POS ON-OFF-ON
Defaults to Auto position when Guarded
START 1 SWITCH
ProSim System: Penumatic
ProSim Group: Switch
ProSim Config Names:
Start 1 Off
Start 1 GRD
Start 1 CONT
Start 1 FLT
Hardware:
Cole P/N 6600-2266 Magnetic Switch
Push in to rotate to GRD position; magnetic hold on GRD position
START 2 SWITCH
ProSim System: Penumatic
ProSim Group: Switch
ProSim Config Names:
Start 2 Off
Start 2 GRD
Start 2 CONT
Start 2 FLT
Hardware:
Cole P/N 6600-2266 Magnetic Switch
Push in to rotate to GRD position; magnetic hold on GRD position
STDBY RUD ON INDICATOR
ProSim System:
Hydraulic
ProSim Group:
Indicator
ProSim Config Names:
Stdby Rud On
Hardware:
N/A
Notes:
None
TAT TEST SWITCH
ProSim System: Heating
ProSim Group: Switch
ProSim Config Names:
TAT test Off
TAT test Pushed
Hardware:
Momentary push button, (ON)-OFF
TEMP PROBE HEAT INDICATOR
TR UNIT INDICATOR
TRANSFER BUS OFF 1 INDICATOR
TRANSFER BUS OFF 2 INDICATOR
TRIM AIR SWITCH
ProSim System: Pneumatic
ProSim Group: Switch
ProSim Config Names:
Trim air Off
Trim air On
Hardware:
Honeywell 1TL1-2D
2-POS ON-OFF
Locked in both positions
TRIP RESET SWITCH
ProSim System: Pneumatic
ProSim Group: Switch
ProSim Config Names:
Trip reset Off
Trip reset On
Hardware:
Momentary push button switch, (ON)-OFF
ProSim Config Names:
OVHT test Off
OVHT test On
VHF NAV SWITCH
ProSim System: Navigation
ProSim Group: Switch
ProSim Config Names:
VHF NAV Normal
VHF NAV Both on 1
VHF NAV Both on 2
Hardware:
Honeywell 1TL1-1A
3-POS ON-OFF-ON
Locking in all three positions
WAI L VALVE OPEN INDICATOR
ProSim System: Heating
ProSim Group: Indicator
ProSim Config Names:
WAI L Valve Open
WAI L Valve Open bright (GATE)*
*This is a dual-brightness indicator. The bright state is a gate. Bright indicates the valve is in transit and dim indicates an full open state.
WAI R VALVE OPEN INDICATOR
ProSim System: Heating
ProSim Group: Indicator
ProSim Config Names:
WAI R Valve Open
WAI R Valve Open bright (GATE)*
*This is a dual-brightness indicator. The bright state is a gate. Bright indicates the valve is in transit and dim indicates an full open state.
WINDOW HEAT FWD L OVERHEAT INDICATOR
ProSim System: Heating
ProSim Group: Indicator
ProSim Config Names:
Window heat FWD L overheat
WINDOW HEAT SIDE L OVERHEAT INDICATOR
ProSim System: Heating
ProSim Group: Indicator
ProSim Config Names:
Window heat Side L overheat
WINDOW HEAT SIDE R OVERHEAT INDICATOR
ProSim System: Heating
ProSim Group: Indicator
ProSim Config Names:
Window heat Side R overheat
WINDOW HEAT FWD R OVERHEAT INDICATOR
ProSim System: Heating
ProSim Group: Indicator
ProSim Config Names:
Window heat FWD R overheat
WINDOW HEAT SIDE L INDICATOR
ProSim System: Heating
ProSim Group: Indicator
ProSim Config Names:
Window heat Side L off*
Window heat Side L on
*Not sure why this item is included. The ON item should be all that’s needed.
WINDOW HEAT FWD L INDICATOR
ProSim System: Heating
ProSim Group: Indicator
ProSim Config Names:
Window heat FWD L off*
Window heat FWD L on
*Not sure why this item is included. The ON item should be all that’s needed.
WINDOW HEAT FWD R INDICATOR
ProSim System: Heating
ProSim Group: Indicator
ProSim Config Names:
Window heat FWD R off*
Window heat FWD R on
*Not sure why this item is included. The ON item should be all that’s needed.
WINDOW HEAT SIDE R INDICATOR
ProSim System: Heating
ProSim Group: Indicator
ProSim Config Names:
Window heat Side R off*
Window heat Side R on
*Not sure why this item is included. The ON item should be all that’s needed.
WINDOW HEAT SIDE L SWITCH
ProSim System: Heating
ProSim Group: Switch
ProSim Config Names:
Window heat Side L Off
Window heat Side L On
Hardware:
Honeywell 1TL1-2
2-POS ON-OFF
WINDOW HEAT FWD L SWITCH
ProSim System: Heating
ProSim Group: Switch
ProSim Config Names:
Window heat FWD L Off
Window heat FWD L On
Hardware:
Honeywell 1TL1-2
2-POS ON-OFF
WINDOW HEAT TEST SWITCH
ProSim System: Heating
ProSim Group: Switch
ProSim Config Names:
Window heat test OVHT*
Window heat test Center
Window heat test PWR TEST*
*=Momentary position (Spring-loaded to Center)
Hardware:
Honeywell 1TL1-7
3-POS (ON)-OFF-(ON)
WINDOW HEAT FWD R SWITCH
ProSim System: Heating
ProSim Group: Switch
ProSim Config Names:
Window heat FWD R Off
Window heat FWD R On
Hardware:
Honeywell 1TL1-2
2-POS ON-OFF
WINDOW HEAT SIDE R SWITCH
ProSim System: Heating
ProSim Group: Switch
ProSim Config Names:
Window heat Side R Off
Window heat Side R On
Hardware:
Honeywell 1TL1-2
2-POS ON-OFF
WING ANTI-ICE SWITCH
ProSim System: Heating
ProSim Group: Switch
ProSim Config Names:
Wing Anti-Ice Off
Wing Anti-Ice On
Wing Anti-Ice hold actuator (GATE)*
Wing Anti-Ice off actuator (GATE)*
*This is a magnetic locking switch. When the magnet is powered by activating the gate, the magnet holds the switch in the ON position.
Hardware:
Microswitch 25ET61-S, Magnetic 28V
2-POS ON-OFF
(alternate Honeywell 1TL1-2 non-magnetic)
WING-BODY OVERHEAT 1 INDICATOR
ProSim System: Pneumatic
ProSim Group: Indicator
ProSim Config Names:
Wing-body overheat 1
WING-BODY OVERHEAT 2 INDICATOR
ProSim System: Pneumatic
ProSim Group: Indicator
ProSim Config Names:
Wing-body overheat 2
WIPER LEFT SWITCH
ProSim System: Misc
ProSim Group: Switch
ProSim Config Names:
Wiper left Park
Wiper left Int
Wiper left Low
Wiper left High
Hardware:
8-Position Rotary Switch (locked to 4 positions)
WIPER RIGHT SWITCH
ProSim System: Misc
ProSim Group: Switch
ProSim Config Names:
Wiper right Park
Wiper right Int
Wiper right Low
Wiper right High
Hardware:
8-Position Rotary Switch (locked to 4)
YAW DAMPER INDICATOR
ProSim System: Misc
ProSim Group: Indicator
ProSim Config Names:
Yaw damper
Hardware:
Notes:
YAW DAMPER SWITCH
ProSim System: Misc
ProSim Group: Switch
ProSim Config Names:
Yaw damper Off
Yaw damper On
Hardware:
25ET61-S
Notes:
Magnetic hold toggle switch. Holds in ON position when 28V DC power applied.
ZONE TEMP CONT CAB INDICATOR
ZONE TEMP FWD CAB INDICATOR
ZONE TEMP AFT CAB INDICATOR
VOICE RECORDER SWITCH
ProSim System: Misc
ProSim Group: Switch
ProSim Config Names:
Voice recorder Auto
Voice recorder On
Hardware:2-POS ON-OFF
VOICE RECORDER ERASE SWITCH
ProSim System: Misc
ProSim Group: Switch
ProSim Config Names:
Voice recorder erase Off
Voice recorder erase Pushed
Hardware: Momentary Push-button Switch
VOICE RECORDER TEST SWITCH
ProSim System: Misc
ProSim Group: Switch
ProSim Config Names:
Voice recorder test Off
Voice recorder test Pushed
Hardware: Momentary Push-Button Switch
VOICE RECORDER STATUS INDICATOR
ProSim System: Misc
ProSim Group: Indicator
ProSim Config Names:
Voice recorder status
Aft Overhead (AFT-OH)
AFT-OH
Click an item in the diagram at right to view its basic ProSim Config properties.
Click the More Info button that appears in this panel to visit the Combined Config reference table where you’ll find more detailed information on the item, if available.
ELT SWITCH
ProSim System: Misc
ProSim Group: Switch
ProSim Config Names:
ELT Arm
ELT On
Hardware:
2-POS ON-OFF
IRS DISP SEL SWITCH
ProSim System: Navigation
ProSim Group: Switch
ProSim Config Names:
IRS Disp Sel TK/GS
IRS Disp Sel Test
IRS Disp Sel PPOS
IRS Disp Sel Wind
IRS Disp Sel HDG/STS
Hardware:
12-POS Rotary Switch, 30 degree detents
IRS SYS DSPL SWITCH
ProSim System: Navigation
ProSim Group: Switch
ProSim Config Names:
IRS SYS DSPL Left
IRS SYS DSPL Right
Hardware:
8-POS rotary switch, limited to 2 positions
LE DEVICES INDICATORS
ProSim System: Misc
ProSim Group: Indicator
ProSim Config Names:
Flaps extended 1
Flaps extended 2
Flaps extended 3
Flaps extended 4
Flaps transit 1
Flaps transit 2
Flaps transit 3
Flaps transit 4
Slats extended 1
Slats extended 2
Slats extended 3
Slats extended 4
Slats extended 5
Slats extended 6
Slats extended 7
Slats extended 8
Slats fullExtended 1
Slats fullExtended 2
Slats fullExtended 3
Slats fullExtended 4
Slats fullExtended 5
Slats fullExtended 6
Slats fullExtended 7
Slats fullExtended 8
Slats transit 1
Slats transit 2
Slats transit 3
Slats transit 4
Slats transit 5
Slats transit 6
Slats transit 7
Slats transit 8
IRS KEYPAD SWITCHES
ProSim System: Navigation
ProSim Group: Switch
ProSim Config Names:
IRS Keypad 0 Off
IRS Keypad 0 Pushed
IRS Keypad 1 Off
IRS Keypad 1 Pushed
IRS Keypad 2 Off
IRS Keypad 2 Pushed
IRS Keypad 3 Off
IRS Keypad 3 Pushed
IRS Keypad 4 Off
IRS Keypad 4 Pushed
IRS Keypad 5 Off
IRS Keypad 5 Pushed
IRS Keypad 6 Off
IRS Keypad 6 Pushed
IRS Keypad 7 Off
IRS Keypad 7 Pushed
IRS Keypad 8 Off
IRS Keypad 8 Pushed
IRS Keypad 9 Off
IRS Keypad 9 Pushed
IRS Keypad CLR Off
IRS Keypad CLR Pushed
IRS Keypad ENT Off
IRS Keypad ENT Pushed
LE DEVICES TEST SWITCH
ProSim System: Misc
ProSim Group: Switch
ProSim Config Names:
LE Devices test Off
LE Devices test Pushed
Hardware:
Momentary push button, (ON)-OFF
IRS LEFT ALIGN INDICATOR
IRS RIGHT ALIGN INDICATOR
IRS LEFT ON DC INDICATOR
IRS RIGHT ON DC INDICATOR
IRS LEFT FAULT INDICATOR
IRS RIGHT FAULT INDICATOR
IRS LEFT DC FAIL INDICATOR
IRS RIGHT DC FAIL INDICATOR
IRS LEFT SWITCH
ProSim System: Navigation
ProSim Group: Switch
ProSim Config Names:
IRS left Nav
IRS left Off
IRS left Align
IRS left Att
Hardware:
IRS RIGHT SWITCH
ProSim System: Navigation
ProSim Group: Switch
ProSim Config Names:
IRS right Nav
IRS right Off
IRS right Align
IRS right Att
Hardware:
PSEU INDICATOR
DOME LIGHT SWITCH
ProSim System: Lighting
ProSim Group: Switch
ProSim Config Names:
Dome light Dim
Dome light Off
Dome light Bright
Domelight bright (GATE)
Domelight dim (GATE)
Domelight master (GATE)
Hardware:
3-POS toggle switch, ON-OFF-ON
REVERSER LEFT INDICATOR
REVERSER RIGHT INDICATOR
ENGINE CONTROL LEFT INDICATOR
ENGINE CONTROL RIGHT INDICATOR
EEC LEFT
ProSim System: Engine
ProSim Group: Indicator & Switch
ProSim Config Names:
EEC left Off (SWITCH)
EEC left Pushed (SWITCH)
EEC left latch Off (SWITCH)
EEC left latch On (SWITCH)
EEC Altn left (INDICATOR)
EEC On left (INDICATOR)
Hardware:
This is a specialized switch/indicator combination. The indicators and switch are controlled via multiple inputs on the back-side of the switch housing. FlightDeck Solutions makes the one I have.
EEC RIGHT
ProSim System: Engine
ProSim Group: Indicator & Switch
ProSim Config Names:
EEC right Off (SWITCH)
EEC right Pushed (SWITCH)
EEC right latch Off (SWITCH)
EEC right latch On (SWITCH)
EEC Altn right (INDICATOR)
EEC On right (INDICATOR)
Hardware:
This is a specialized switch/indicator combination. The indicators and switch are controlled via multiple inputs on the back-side of the switch housing. FlightDeck Solutions makes the one I have.
OXYGEN PRESSURE GAUGE
GEAR LEFT AFT OVH INDICATOR
ProSim System: Landing Gear
ProSim Group: Indicator
ProSim Config Names:
Gear left aft ovh
GEAR RIGHT AFT OVH INDICATOR
ProSim System: Landing Gear
ProSim Group: Indicator
ProSim Config Names:
Gear right aft ovh
GEAR NOSE AFT OVH INDICATOR
ProSim System: Landing Gear
ProSim Group: Indicator
ProSim Config Names:
Gear nose aft ovh
PASS OXY ON INDICATOR
PASS OXYGEN SWITCH
ProSim System: Pneumatic
ProSim Group: Switch
ProSim Config Names:
Pass oxygen Normal
Pass oxygen On
Hardware:
2-POS ON-OFF guarded toggle switch
Switch is in the NORMAL position when guarded.
FLIGHT RECORDER SWITCH
ProSim System: Misc
ProSim Group: Switch
ProSim Config Names:
Flight recorder Normal
Flight recorder Test
Hardware:
2-POS ON-OFF guarded toggle switch
Switch is in the Normal position when guard is closed.
FLIGHT RECORDER OFF INDICATOR
MACH AIRSPEED WARNING TEST NO1 SWITCH
ProSim System: Misc
ProSim Group: Switch
ProSim Config Names:
Mach Airspeed warning test no1 Off
Mach Airspeed warning test no1 Pushed
Hardware:
Momentary push button, (ON)-OFF
MACH AIRSPEED WARNING TEST NO2 SWITCH
ProSim System: Misc
ProSim Group: Switch
ProSim Config Names:
Mach Airspeed warning test no2 Off
Mach Airspeed warning test no2 Pushed
Hardware:
Momentary push button, (ON)-OFF
STALL TEST 1 SWITCH
ProSim System: Misc
ProSim Group: Switch
ProSim Config Names:
Stall test 1 Off
Stall test 1 Pushed
Hardware:
Momentary push button, (ON)-OFF
STALL TEST 2 SWITCH
ProSim System: Misc
ProSim Group: Switch
ProSim Config Names:
Stall test 2 Off
Stall test 2 Pushed
Hardware:
Momentary push button, (ON)-OFF
IRS DISPLAY LCD
ProSim System: Navigation
ProSim Group: LCD
ProSim Config Names:
IRS Display
IRS Display left char state (NUMERICAL)
IRS Display left mode (NUMERICAL)
IRS Display left number (NUMERICAL)
IRS Display right char state (NUMERICAL)
IRS Display right mode (NUMERICAL)
IRS Display right number (NUMERICAL)
ILS INDICATOR
ProSim System: Misc
ProSim Group: Indicator
ProSim Config Names:
ILS
GLS INDICATOR
ProSim System: Misc
ProSim Group: Indicator
ProSim Config Names:
GLS
ASP OBS PANEL
ProSim System: Communication
ProSim Group: Switch / Indicator / Analog
ProSim Config Names:
Too many items to list here. Click the More Info link to go to the detailed config items.
Main Instrument Panel – Captain (MIP-CAPT)
MIP-CAPT
Click an item in the diagram at right to view its basic ProSim Config properties.
Click the More Info button that appears in this panel to visit the Combined Config reference table where you’ll find more detailed information on the item, if available.
BELOW G/S P-INHIBIT INDICATOR
NOSE WHEEL STEERING SWITCH
ProSim System: Landing Gear
ProSim Group: Switch
ProSim Config Names:
Nose wheel steering Normal
Nose wheel steering Alternate
MAIN PANEL DUS SWITCH
ProSim System: MIP
ProSim Group: Switch
ProSim Config Names:
Main Panel DUs Capt Norm
Main Panel DUs Capt Outbd PFD
Main Panel DUs Capt Eng Pri
Main Panel DUs Capt PFD
Main Panel DUs Capt MFD
LOWER DU CAPT SWITCH
ProSim System: MIP
ProSim Group: Switch
ProSim Config Names:
Lower DU Capt Norm
Lower DU Capt ND
Lower DU Capt Eng Pri
CHRONO CAPT CHR SWITCH
ProSim System: MIP
ProSim Group: Switch
ProSim Config Names:
Chrono capt CHR Normal
Chrono capt CHR Pushed
CHRONO CAPT DATE/TIME SWITCH
ProSim System: MIP
ProSim Group: Switch
ProSim Config Names:
Chrono capt Date/Time Normal
Chrono capt Date/Time Pushed
CHRONO CAPT SET SWITCH
ProSim System: MIP
ProSim Group: Switch
ProSim Config Names:
Chrono capt SET Normal
Chrono capt SET Pushed
CHRONO CAPT + SWITCH
ProSim System: MIP
ProSim Group: Switch
ProSim Config Names:
Chrono capt + Normal
Chrono capt + Pushed
CHRONO CAPT – SWITCH
ProSim System: MIP
ProSim Group: Switch
ProSim Config Names:
Chrono capt – Normal
Chrono capt – Pushed
CHRONO CAPT RESET SWITCH
ProSim System: MIP
ProSim Group: Switch
ProSim Config Names:
Chrono capt RESET Normal
Chrono capt RESET Pushed
CHRONO CAPT ET SWITCH
ProSim System: MIP
ProSim Group: Switch
ProSim Config Names:
Chrono capt ET Normal
Chrono capt ET Pushed
CHRONO CAPT ALTERNATE CONTROL
ProSim System: MIP
ProSim Group: Switch
ProSim Config Names:
Chrono capt alternate control Run
Chrono capt alternate control Hold
Chrono capt alternate control Reset
Notes:
This rotary switch is used on the older style Chronos as pictured.
CAPT ASA A/P INDICATOR
ProSim System: MIP
ProSim Group: Indicator
ProSim Config Names:
ASA A/P Amber Capt
ASA A/P Red Capt
CAPT ASA A/P RESET SWITCH
ProSim System: MIP
ProSim Group: Switch
ProSim Config Names:
ASA A/P reset Capt Off
ASA A/P reset Capt Pushed
CAPT ASA A/T INDICATOR
ProSim System: MIP
ProSim Group: Indicator
ProSim Config Names:
ASA A/T Amber Capt
ASA A/T Red Capt
CAPT ASA A/T RESET SWITCH
ProSim System: MIP
ProSim Group: Switch
ProSim Config Names:
ASA A/T reset Capt Off
ASA A/T reset Capt Pushed
CAPT ASA FMC INDICATOR
CAPT ASA FMC RESET SWITCH
ProSim System: MIP
ProSim Group: Switch
ProSim Config Names:
ASA FMC reset Capt Off
ASA FMC reset Capt Pushed
SPEEDBRAKE ARMED INDICATOR
SPEEDBRAKE DO NOT ARM INDICATOR
STAB OUT OF TRIM INDICATOR
STAB OUT OF TRIM SWITCH
ProSim System: MIP
ProSim Group: Switch
ProSim Config Names:
Stab out of trim PTT Normal
Stab out of trim PTT Pushed
CAPT ASA TEST SWITCH
ProSim System: MIP
ProSim Group: Switch
ProSim Config Names:
ASA Test Capt Off
ASA Test Capt 1
ASA Test Capt 2
LIGHT TEST SWITCH
ProSim System: Lighting
ProSim Group: Switch
ProSim Config Names:
Light Test Bright
Light Test Dim
Light Test Test
UPPER DU BRIGHTNESS KNOB
LEFT OUTBOARD DU BRIGHTNESS KNOB
LEFT INBOARD BRIGHTNESS KNOBS
ProSim System: MIP
ProSim Group: Analog
ProSim Config Names:
Left Inboard Brightness
Left Inboard Brightness Inner
LOWER DU BRIGHTNESS KNOBS
ProSim System: MIP
ProSim Group: Analog
ProSim Config Names:
Lower DU Brightness
Lower DU Brightness Inner
MCP BACKGROUND LIGHT KNOB
ProSim System: Lighting
ProSim Group: Analog / Numerical
ProSim Config Names:
MCP background light (Analog)
MCP background light output (Numerical)
AFDS FLOOD LIGHT KNOB
ProSim System: Lighting
ProSim Group: Analog / Numerical
ProSim Config Names:
AFDS flood light (Analog)
AFDS flood light output (Numerical)
MAIN PANEL BRIGHTNESS KNOB
ProSim System: Lighting
ProSim Group: Analog / Numerical
ProSim Config Names:
Panel lights (Analog)
Panel lights output (Numerical)
Main Instrument Panel – Center (MIP-CENTER)
MIP-CENTER
Click an item in the diagram at right to view its basic ProSim Config properties.
Click the More Info button that appears in this panel to visit the Combined Config reference table where you’ll find more detailed information on the item, if available.
AUTO BRAKE DISARM INDICATOR
AUTOBRAKE SWITCH
ProSim System: Landing Gear
ProSim Group: Switch / Gate
ProSim Config Names:
Autobrake Off (Switch)
Autobrake RTO (Switch)
Autobrake 1 (Switch)
Autobrake 2 (Switch)
Autobrake 3 (Switch)
Autobrake Max (Switch)
Autobrake disarm PTT Normal (Switch)
Autobrake disarm PTT Pushed (Switch)
Autobrake reset (Gate)
N1 SET KNOBS
ProSim System: MIP
ProSim Group: Switch
ProSim Config Names:
N1 SET AUTO
N1 SET 1
N1 SET 2
N1 SET Both
N1 SET Rotary momentary Center
N1 SET Rotary momentary Up
N1 SET Rotary momentary Down
N1 SET Rotary momentary Up fast
N1 SET Rotary momentary Down fast
N1 SET Rotary pulse down Off
N1 SET Rotary pulse down On
N1 SET Rotary pulse up Off
N1 SET Rotary pulse up On
SPEED REF KNOBS
ProSim System: MIP
ProSim Group: Switch / Encoder
ProSim Config Names:
SPD REF AUTO (Switch)
SPD REF V1 (Switch)
SPD REF VR (Switch)
SPD REF WT (Switch)
SPD REF VREF (Switch)
SPD REF BUG (Switch)
SPD REF SET (Switch)
SPD REF Rotary momentary Center (Switch)
SPD REF Rotary momentary Up (Switch)
SPD REF Rotary momentary Down (Switch)
SPD REF Rotary momentary Up fast (Switch)
SPD REF Rotary momentary Down fast (Switch)
SPD REF Rotary pulse down Off (Switch)
SPD REF Rotary pulse down On (Switch)
SPD REF Rotary pulse up Off (Switch)
SPD REF Rotary pulse up On (Switch)
SPD REF Rotary (Encoder)
MFD ENG SWITCH
ProSim System: MIP
ProSim Group: Switch
ProSim Config Names:
MFD ENG Normal
MFD ENG Pushed
MFD SYS SWITCH
ProSim System: MIP
ProSim Group: Switch
ProSim Config Names:
MFD SYS Normal
MFD SYS Pushed
ANTI SKID INOP INDICATOR
LE FLAPS TRANSIT INDICATOR
LE FLAPS EXT INDICATOR
FLAPS GAUGE
ProSim System: MIP
ProSim Group: Gauge / Numerical
ProSim Config Names:
Flap (position of single or L needle)
Flap right (position of R needle)
Flap numerical (numerical output value of L needle)
Flap right numerical (numerical output value of R needle)
FUEL FLOW SWITCH
ProSim System: MIP
ProSim Group: Switch
ProSim Config Names:
Fuel flow Rate
Fuel flow Used
Fuel flow Reset
YAW DAMPER GAUGE
ProSim System: MIP
ProSim Group: Gauge / Numerical
ProSim Config Names:
Yaw damper gauge (Gauge)
Yaw damper gauge numerical (Numerical)
ISFD APP SWITCH
ISFD HP/IN SWITCH
ProSim System: MIP
ProSim Group: Switch
ProSim Config Names:
ISFD HP/IN Off
ISFD HP/IN Pushed
ISFD + SWITCH
ISFD – SWITCH
ISFD RST SWITCH
ISFD BARO KNOB
ProSim System: MIP
ProSim Group: Switch
ProSim Config Names:
ISFD baro STD Off
ISFD baro STD Pushed
ISFD baro encoder pulse down Off
ISFD baro encoder pulse down On
ISFD baro encoder pulse up Off
ISFD baro encoder pulse up On
STANDBY RMI NAV1 SWITCH
ProSim System: MIP
ProSim Group: Switch
Standby RMI NAV1 mode VOR
Standby RMI NAV1 mode ADF
STANDBY RMI NAV2 SWITCH
ProSim System: MIP
ProSim Group: Switch
Standby RMI NAV2 mode VOR
Standby RMI NAV2 mode ADF
Main Instrument Panel – First Officer (MIP-FO)
MIP-FO
Click an item in the diagram at right to view its basic ProSim Config properties.
Click the More Info button that appears in this panel to visit the Combined Config reference table where you’ll find more detailed information on the item, if available.
NOSE GEAR INDICATOR (RED)
ProSim System: Landing Gear
ProSim Group: Indicator
ProSim Config Names:
Gear nose transit
NOSE GEAR INDCATOR (GREEN)
Mode Control Panel (MCP)
MCP
Click an item in the diagram at right to view its basic ProSim Config properties.
Click the More Info button that appears in this panel to visit the Combined Config reference table where you’ll find more detailed information on the item, if available.
Test
Electronic Flight Instrument System (EFIS)
EFIS
Click an item in the diagram at right to view its basic ProSim Config properties.
Click the More Info button that appears in this panel to visit the Combined Config reference table where you’ll find more detailed information on the item, if available.
Test
Glare Wings
Glare
Click an item in the diagram at right to view its basic ProSim Config properties.
Click the More Info button that appears in this panel to visit the Combined Config reference table where you’ll find more detailed information on the item, if available.
Test
Computer Display Units (CDU), Throttle Quadrant (TQ), and Center Pedestal
CDU-TQ-Pedestal
Click an item in the diagram at right to view its basic ProSim Config properties.
Click the More Info button that appears in this panel to visit the Combined Config reference table where you’ll find more detailed information on the item, if available.